- EN -
MAINTENANCE AND CLEANING
Replacing the filter felt in the unit
D
1. Turn the unit over and replace both felt discs in the housing base.
2. Reassemble the unit in the reverse order.
Replacing the filter felt in the diffuser
D
1. Take the diffuser out of the water.
2. Open the diffuser using a coin or flat head and replace the felt disc.
3. Close the diffuser again.
10
OxyMax 100/200/400
TROUBLESHOOTING
Malfunction
Cause
Unit does not start up
Not connected to power
Diffuser soiled
Filter felt in the pump or
The unit does not deliver
aerator worn
any air or the amount
delivered is insufficient.
Air tube kinked or porous
Membrane is defective
The unit is unusually loud Membrane is defective
WEAR PARTS
The following components are wear parts and are excluded from the warranty:
• Diffuser, filter felt discs, membrane
DISPOSAL
NOTE
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the
unit via the return system provided for this purpose.
SPARE PARTS
The use of original parts from OASE ensures continued safe and reliable operation of
the unit. Please visit our website for spare parts. https://www.oase-livingwater.com
- EN -
Remedy
Check the power
Clean or replace the diffuser
Replace the filter felt
Lay the air tube without
kinks or replace
Replace the membrane
Replace the membrane
11