Error Indications; Inspection And Replacement Of Soldering Iron Handle; Inspection Of Heating Element And Sensor Assembly; Replacement Of Heating Core By Disassembling Soldering Iron Handle - SATA 02003 Manual Del Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 100

9. Error Indications

The soldering station will display various error indicators in case of any problem. Refer to the "Inspection and Replacement
of Soldering Iron Assembly" if the following indicators are displayed.
S-E Sensor error: If any part of the sensor or its circuit fails, the "S-E" indicator will be displayed and the current supplied
to the soldering iron handle will be cut off.
H-E Heating element error: If the soldering station cannot supply power to the heating element, the window displays "H-E"
indicator, indicating that the heating core may be damaged.

10. Inspection and Replacement of Soldering Iron Handle

When the soldering iron handle fails, do inspection to identify the damaged component before replacement.

10.1 Inspection of Heating Element and Sensor Assembly

1 )
Unplug the plug and determine the resistance between the pins of the connecting plug according to the table below.
2)
If the resistances "a" and "b" are different from those listed in the table below, replace the heating element(or
sensor)or the handle wire.
3)
If the resistance "c" is greater than that listed in the following table, gently wipe the oxide layer at the position shown
in the figure below with abrasive paper or steel wool.
a.
Pin 1 to pin 5(heating element)
b.
Pin 1 to pin 3(sensor)
c.
Pin 3 to soldering bit

10.2 Replacement of Heating Core by Disassembling Soldering Iron Handle

1 )
Unscrew the soldering bit set nut and remove the soldering bit steel casing pipe and the soldering bit.
2)
Unscrew the fixing insert from the handle assembly.
3)
Pull the heating core assembly and the handle wire out from the handle(toward the soldering bit).
4)
Pull the handle wire clip out from the plastic locater notch and pull the handle wire connector out from the pin.
5)
Remove the plastic locater and the spring, and then replace the heating core assembly with a new one.

10.3 Measurement when the Heating Element Cools Down to Room Temperature

1 )
Resistance of the heating element(red & blue): 12-14 Ω.
Resistance of the sensor(Resistance of the sensor): <10 Ω.
2)
26
02003
Tested Pin
中文
EN
Ceramic Heating Element
12 ~ 14Ω(normal)
<10Ω(normal)
< 2 Ω
DE RU KO PT
JA
3
4
5
ES
2
1

Publicidad

Tabla de contenido
loading

Tabla de contenido