When the low battery symbol appears on the screen, replace the battery immediately.
Low battery can cause false readings, resulting in electric shock or personal injury.
●
Do not use the probes included in the meter on other meters.
●
Do not use the meter when the user's hand or environment is humid, or when the meter
is humid.
●
When a dangerous voltage is supplied to an input terminal, please note that this voltage
may be supplied to all the other terminals.
●
Remove the probes and head from the measured conductor or circuit before rotating
the function/position switch.
Electrical symbols
Symbol
AC
DC
AC or DC
Caution! Danger! Please read the instruction before use.
Ground terminal
Meter with double or strengthened insulation protection
Caution! Risk of electric shock!
In compliance with EU Directives
General characteristics
1. Highest voltage between "INPUT" terminal and ground: 1000V rms
2.03025 display: 33/4-digit LCD (with a maximum reading of 9999 for frequency
measurement)
03026 display: 3 5/6-digit LCD (with a maximum reading of 9999 for frequency
measurement)
3. Sampling rate: 2~3 times/s
4. Operating temperature: 0°C~40°C, relative humidity: < 75%
5. Additional temperature coefficient: 0.2 × specified accuracy/°C (<18°C or 28°C)
6. Storage temperature: -30°C~60°C, relative humidity: < 85%
7. Negative polar indication: "-" shown on the screen
8. Overrange indication: "OL" shown on the screen
03025/03026