Installation; Installation Notes; Mounting Location Requirements - inti CEDRO+ Serie Manual De Usuario

Controlador mppt
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION

CAUTION: PLEASE READ ALL INSTRUCTIONS AND PRECAUTIONS IN THE MANUAL
BEFORE PROCEEDING WITH THE INSTALLATION! IT IS RECOMMENDED TO REMOVE THE
PROTECTIVE FILM COVER FROM THE LCD SCREEN BEFORE OPERATION
NSTALLATION NOTES
This charge controller must only be used in PV systems in accordance with requirements given in this user manual and the specifications of other
system components provided by their manufacturers. No energy source other than a PV generator may be connected to the PV charge controller
referred herein.
PV-modules must always be disconnected prior to the installation and adjustments of the charge controller; Make sure the circuit breaker, fuse or
disconnects of battery terminal are turned off.
Double check whether battery voltage meets the voltage range of Charge Controller.
Batteries store a large amount of energy, never short circuit a battery under any circumstances. We strongly recommend connecting a protection
fuse directly to the battery terminal for protection in case of short circuiting the battery.
Batteries can produce flammable gases. Avoid provoking any sparks, using fire or any exposed flame close to any batteries, ever. Make sure that
the battery room is well ventilated to disperse any gases.
Only use insulated tools and avoid placing (any) metal objects near/close to batteries.
Be extremely cautious when working with batteries. Wear eye protection. Have fresh water available to immediately wash and clean any contact
with battery acid. Get immediately medical aid in case of any hazard that may occur. Never install/handle with batteries alone.
Avoid touching or short-circuiting wires or terminals. Be aware that voltages on given system components, terminals or wires can be a multiple of
battery voltage. Only use insulated tools, stand on dry ground, and keep your hands always dry and protected by proper (approved) electrician
gloves when working on PV-Systems.
Prevent any water, ever, from penetrating the controller, outdoor installation must avoid any direct sunlight and penetration of any water (e.g., rain)
and humidity.
After installation make sure that all connections are properly tighten, eliminate any electrical loose connections to eliminate any hot electrical
connection spots.

MOUNTING LOCATION REQUIREMENTS

Do not subject the PV charge controller to direct sunlight or any other heat sources. Protect the PV charge controller from any dust, dirt, and
moisture. Mount it flat to a vertical wall. Must be a non-flammable material. Maintain a minimum clearance of 15 cm below and around the controller
to ensure unhindered air circulation. Mount the PV charge controller not too far from the batteries (for accurate voltage sensing least lessening).
Mark the position of the PV charge controller fastening holes on the wall, drill 4 holes and insert dowels, fasten the PV charge controller to the wall