When the LCD shows as displayed on top, press the MENU key for 1s, the icon flashes, you can set the battery type:
Charging Voltage Parameters (Liquid, GEL, AGM):
When choosing Liquid, GEL or AGM for battery type, the parameters of boost, equalization and float charge voltage can be set by mobile phone
APP, RS485. The range of parameters is as follows.
The following voltage parameters are 25C/12V system parameters, 24/48V displayed values are multiplied by a factor of 2/4.
Charging stage
Charging Voltage Range
Default Charging voltage
Charging Voltage Parameters (Lithium):
When choosing lithium battery type, the overcharge protection and overcharge recovery voltage of lithium battery can be set by mobile phone APP,
or RS485.
Lithium overcharge protection voltage range: 10.0-32.0V (default:14.4V)
Lithium overcharge recovery voltage setting range: 9.2-31.8V (default:14.0V)
NOTE:
(Overcharge Recovery Voltage+1.5V) ≥ Lithium Overcharge Protection Voltage≥ (Overcharge Recovery
Voltage+0.2V)
Warning: The required accuracy of BMS shall be at least 0.2V. If tolerance is larger than 0.2V,
manufacturer will not assume any liability for any consequent system malfunction
Load mode
www.intipv.com
Display
Battery type
GEL (default)
Liquid
AGM
Lithium
Boost
14,0-14,8V
14,5V
Equalization
14,0-15,0V
14,8V
MANUAL DE USUARIO CONTROLADOR CEDRO PLUS
Float
13,0-14,5V
13,7V
39