BFT LEO B CBB 3 400 W01 Instrucciones De Instalación página 16

Ocultar thumbs Ver también para LEO B CBB 3 400 W01:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an attempt
is made to log in, the display will read "BLOC". The default password is 1234.
8) OPEN IN OTHER DIRECTION (Fig. D1)
9) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. B) Refer to specific manual.
10) RADIO-RECEIVER (Fig. B)
The board comes ready for connection of removable radio-receiver.
The receiver's channel 1 controls input IC1.
The receiver's channel 2 controls terminals 26-27.
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using
an appropriate antenna tuned to 433MHxz.
12) RESTORING FACTORY SETTINGS (Fig.G)
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.G ref.1)
- Open the Stop input and press the - and OK keys together (Fig.G ref.2)
- Switch on the board's power (Fig.G ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.G ref.4)
- Wait for the procedure to finish (Fig.G ref.5)
- Procedure finished (Fig.G ref.6)
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
120
TCA
partial
1
99
opening
1
99
OP. F ORCE
1
99
CLS. F ORCE
Rev. Dis.
0
200
space
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Pre-alarm
PRE-ALARM
16 -
LEO B CBB 3 400 W 01
INSTALLATION MANUAL
Default
Personal
Definition
10
Automatic closing time [s]
40
Partial opening [%]
Leaf force during opening
80
[%]
Leaf force during closing
80
[%]
0
Reverse disabling space
Programming number of
operations for maintenance
0
threshold
[in hundreds]
Cross
out
Default
setting
used
0
 
Time
0
 
0
 
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Waiting time before automatic closing.
Adjusts partial opening percentage compared to total opening in "Partial open" mode.
Force exerted by leaf/leaves during opening. This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary.
Force exerted by leaf/leaves during closing. This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices
where necessary.
Disables obstacle/curb detection near the limit stop in closing
0 = no disabling 200 = disabling Maximum
WARNING: It affects impact force directly: make sure that current safety require-
ments are met with the set value (*). Install anti-crush safety devices where necessary.
Allows you to set a number of operations after which the need for maintenance will be reported
on the AUX output configured as Maintenance or Flashing Light and Maintenance .
0
Logic not enabled
1
Switches automatic closing on
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

U-link

Tabla de contenido