is indicated on the display. By means of the buttons C(-) and D(+) the desired sensitivity is set Store the "new" sensitivity
by pressing the key E.
ATTENTION: TO PREVENT DAMAGING THE SENSOR, DO NOT USE SILICONE PRODUCTS NEAR THE HOOD!
CONTROLS of Fig. 20:
A) Reduces the luminous intensity to minimum. When the key is pressed for 2" the lights go off.
B) Switches on the lights calling the last level of luminous intensity set. Increases the luminous intensity to maximum.
C) Reduces the motor speed until reaching minimum. If pressed for 2", the motor is switched off.
If pressed for 2" when the Filter Alarm is active, the HOUR counter is reset.
D) Drives the motor (calling the last speed used) and increases the speed until reaching maximum.
E) Activates/deactivates the sensor (AUTOMATIC or MANUAL mode). In Automatic mode the sensor is active and
the letter "A" appears on the display (L).
L) Display:
- signals the running speed.
- signals Automatic mode by displaying the letter "A". When the motor speed is changed, the running speed is
displayed flashing times, and then the letter "A" reappears.
- signals the filter alarm (with motor off) by displaying the central segment for 30".
FILTER ALARM: Displayed for 30" when the motor is off:
After 30h of operation, the letter "F" appears on the display; It indicates that the grease filters need to be cleaned.
After 120h of operation, the letter "F" flashes on the display; It indicates that the grease filters need to be cleaned and
the charcoal filters replaced.
After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing
the key C during display of the filter alarm.
GAS SENSOR SENSITIVITY: The sensitivity of the sensor can be modified to suit your requirements. To modify the
sensitivity, the appliance must be in manual mode (i.e. the running speed and not the letter "A" must appear on the
display); If not, press the key E.
Modify the sensitivity by simultaneously pressing the keys D and E. The set sensitivity is indicated on the display.
By means of the buttons C(-) and D(+) the desired sensitivity is set Store the "new" sensitivity by pressing the key
E.
ATTENTION: TO PREVENT DAMAGING THE SENSOR, DO NOT USE SILICONE PRODUCTS NEAR THE HOOD!
Grease filters: special attention must be given to the grease filters which must be periodically cleaned, whenever
the grease filter alarm trips. For instructions of the filter Alarm, refer to the Controls paragraph. Remove the filters
as shown in para. 1 and wash with neutral detergent.
Charcoal filters: if the filtering version appliance is used, the charcoal filters will have to be periodically replaced
when the charcoal filter alarm trips. For instructions on the filter Alarm, refer to the Controls paragraph. Removing
the charcoal filter/s: take away the metallic grille (Fig.3a) and the grease filter (Fig.3b). Remove the coal filter pushing
the lock inside, rotate the filter until taking away the two small tongues from their sides (Fig.16).
Lighting: to reach the lamps you remove the metallic support tightening the two screws (Fig.21) and moving
it oo the right ; to replace the halogen lamps tighten the locknut in the anti-clockwise direction and pull out the
bulb (Fig.22). Replace the lamps of the same type.