LED Area/Site Luminaire Installation Instructions
TM
Tools Required
#2 Phillips screw driver, Drill and 7/16" drill bit, Ratchet
and 9/16" socket.
Mast Arm Adapter Mount (FIG. 3)
1.
Loosen (3) screws located in the access door of the
fixture and open the door.
2.
Pull all supply wires through the mast arm/mast
arm adapter and into the center grommet located
between the mounting bolts at the back of the
fixture.
3.
Install the 1st mounting bolt (1/2"-13 x 1 1/4") and
lockwasher through the top side hole at the back of
the fixture and into the mast arm adapter.
4.
Install the 2nd mounting bolt (1/2"-13 x 1 1/4") and
lockwasher through the bottom side hole at the back
of the fixture and into the mast arm adapter.
5.
Slip the assembly over the mast arm (making sure
not to pinch any supply leads). Make sure the mast
arm is fully seated into the mast arm adapter as it
should bottom out against the adapter.
6.
Secure the mast arm adapter to the mast arm with
the (4) 3/8-16 x 3/8" set screws.
7.
Drill a 7/16" hole through the mast arm and install
the 3/8" carriage bolt and nut. Use care when
drilling this hole so as not to damage any wires
within the mast arm.
8.
Inside the fixture, connect supply wires to
appropriate fixture leads:
a. Supply side ground wire to green fixture lead.
b. Supply side neutral wire to white fixture lead.
c. Supply side line voltage wire to black fixture lead.
9.
Close the cover and tighten the three screws to
insure the fixture will maintain it's water tight seal.
FIG. 3
1/2"-13 x 1-1/4"
Mounting Bolt and
Lockwashers
4
LED Area/Site Luminaire Installation Instructions IMI-811 ADH140439 www.eaton.com
Galleon
TM
Photocontrol Orientation (If Equipped)
Note: The orientation procedure is only required for
1.
Loosen the two screws to allow rotation of the
receptacle.
2.
Insert screwdriver into center slot and rotate
receptacle until indicator arrow points north.
3.
Retighten screws.
4.
Insert the photoelectric control (or shorting cap) into
receptacle and twist into locked position.
Note: The photocontrol (not included) must contain
Bi-Level Switching (If Equipped)
For Bi-level switching, the input leads to the fixture
will be independently labeled to indicate dimming
preferences as appropriate (as defined by the order
requirements). Two separate supply lines of line voltage,
neutral and ground must be connected to the fixture
leads to enable the bi-level switching functionality of the
fixture.
Maintenance
A regular maintenance schedule should be followed to
retain optimal light output and thermal performance.
Optical lens cleaning should be performed with a clean
dry cloth to remove any dust or other contaminants.
Additional cleaning can be performed with non-abrasive
Mast Arm
acrylic cleansing solution.
Adapter
3/8"-16
Carriage
Bolt
Set Screws
Insert Over
Mast Arm
photocontrols which specifically require the
cell to be aimed north. Otherwise pre-selected
factory orientation will function properly. Follow
the directions recommended by the photocontrol
supplier for proximity to light sources. Lighted
signs, building surface reflection, floodlights,
tree branches, etc. may affect final position of
the photocontrol.
a soft, resilient gasket fastened to the bottom
surface to assure a proper weather seal between
the control and the receptacle.