5.3 levelling of the appliance

To adjust the final height of the Ecomonoblocco
(fire bed height of the lining), simply act on
the adjustment screws on the legs. Adjust the
screws (Fig. 6: A-adjustment screw, b-fire bed
height), until the marble cover profile is brought
Ecomonoblocco to the required height with re-
spect to the lining, making sure that the base of
the fire box is level.
A

5.4 Assembly diagram

In Fig. 7 there is an example of an assembly
diagram.
A) Chimney flue
b) External air intake
c) Heat recovery grate
D) Counter-hood
and
structure
E) Fume channel
F) Inspection panel
G) Air recirculation grate
H) Min. distance 5 mm between lining and
Ecomonoblocco
Correct installation of the fume duct between
theEcomonoblocco and the fireplace must be
watertight, sealing all the linking joints (A - Fig.
7) with material suitable for high temperatures.
If Ecomonobloccois installed on a fireplace pre-
viously used by other fire boxes, it is necessary to
carry out thorough cleaning to avoid abnormal
functioning and to prevent possible igniting of
any unburned products that may be deposited
on the inner walls of the same.
The installation requires the installation of a heat
recovery grate as close as possible to the ceiling
(approximately 20 cm) (c - Fig. 7).
004778411 - 18/09/2020
ITALIANO
ENGLISH
5 mm
B
Fig. 6
fireproof
load-bearing
DEUTSCH
Incorrect installation can compromise
the safety of the appliance.
The lining must be made of fireproof
material.
In presence of flammable structures or
other materials behind or besides the
fire box, respect the minimum safety
distances reported on the product
booklet.
C
D
E
G
H
The image is purely
L'immagine è puramente
indicativa.
indicative.
The system must be equipped with
earthing and with a differential switch
in compliance with the laws in force.
The flue gas exhaust duct must have
its own earth connection.
All combustible materials that are in the area
of heat radiation from the door glass must be
placed at a distance from it of at least 100  cm
(Fig. 8).
FRANÇAIS
ESPAÑOL
A
F
B
Fig. 7
27