Care And Maintenance - K2 Pumps WPS05003K Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Open the faucet closest to the pump/tank a small amount to allow air to escape the system.
3. Power on! Start the pump.
4. If you don't have water, stop the pump and remove the fill plugs. Refill the pump and piping. You may have to
repeat this two or three times in order to get all the trapped air out of the piping.
5. After the pump has built up pressure in the system and shut off, check the pressure switch operation by opening a
faucet or two and running enough water out to bleed off pressure until the pump starts. The pump should start
when pressure drops to 30 PSI and stop when pressure reaches 50 PSI. Run the pump through one or two
complete cycles to verify correct operation. This will also help clean the system of dirt and scale dislodged during
installation.
Congratulations on a successful installation.
If you were unsuccessful, please refer to Troubleshooting or call our customer service technical staff.

CARE AND MAINTENANCE

WARNING: Disconnect power and release all pressure from the system before attempting to install, service, relocate
or perform any maintenance.
Winterizing
CAUTION: Drain the entire system if there is danger of
freezing. A drain plug is provided at the bottom of the pump
case for this purpose.
Drain openings are provided on all models to drain the
pump:
Unplug the pump from power supply outlet.
Remove drain plug close to the inlet hole.
Drain all piping to a point below the freeze line. This will
drain the pump.
NOTE: While this will drain the pump, it will not necessarily drain all the unprotected parts of the piping system. To
drain tank, disconnect the piping at the tank outlet.
SEAL ASSEMBLY REPLACEMENT
Make certain that the power supply is disconnected before attempting to service the unit! The
CAUTION:
rotary seal assembly must be handled carefully to avoid damaging the precision lapped faces of the sealing
components.
1. Disengage pump body (Ref. No. 9) from motor mounting ring (Ref. No. 11).
2. Remove diffuser (Ref. No. 6).
3. Remove the rear cover(Ref. No. 13) .Remove the impeller(Ref. No. 5) use a 9/16" open end wrench to hold the
motor shaft.
For Professional Technical Support call 1-844-242-2475
15

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wps07503kWps05002tk

Tabla de contenido