RML9430, RML9431, RML9435
Gas operation (fig. 6, page 4)
!
WARNING! Fire hazard!
Never operate the refrigerator with gas at petrol stations.
I
NOTE
When operating with LPG, the burner must be cleaned frequently
(two or three times a year).
➤ Make sure that the gas supply is turned on.
➤ Turn the power selector switch to the
➤ Turn the temperature control to the maximum level (A).
➤ Press in the temperature regulator and hold it down.
➤ Press in the battery igniter as well and hold it down (B).
✓ The burner is ignited automatically. The needle of the pilot light moves to
the green zone once the burner has ignited (C).
➤ Press and hold down the temperature regulator for another 15 seconds.
7.3
Switching on the refrigerator (RML9431/RML9435)
➤ Press and hold the
✓ The refrigerator starts with the last type of power selected.
Operating with AC power supply
➤ Press the
button.
Operating with DC power supply
I
NOTE
Only select the operating mode with direct current (battery mode)
if the vehicle engine is running and is providing sufficient voltage
to the light system or if you are using a battery monitor.
➤ Press the
button.
EN
position.
button for two seconds.
Using the refrigerator
23