Troubleshooting
Displayed faults and signal tone (RML9431 and RML9435 only)
Faults are indicated by the flashing of individual buttons on the control panel,
a beep or a combination of both.
Display
With AC operation:
and
flashing, a
beep is emitted for
20 seconds
With DC operation:
and
flashing, a
beep is emitted for
20 seconds
and
flashing, a
beep is emitted for
20 seconds
and bright
flashing
flashes
With AC operation:
and
flashing, a
beep is emitted for
20 seconds
With DC operation:
and
flashing, a
beep is emitted for
20 seconds
With gas and automatic
operation:
and
flashing, a
beep is emitted for
20 seconds
With gas operation:
and bright
flashing
34
Problem
The AC heating
element is defective.
The DC heating
element is defective.
The burner or the
cooling unit is defec-
tive.
The burner or the
cooling unit is defec-
tive.
The temperature
sensor has no contact
or is defective.
The power supply is
not available or insuffi-
cient.
The power supply is
not available or insuffi-
cient.
The burner flame is not
ignited.
The burner flame is not
ignited.
RML9430, RML9431, RML9435
Suggested remedy
Contact the authorised
customer service.
Check the AC power cable, the
power supply and the fuse.
Check the DC power cable, the
vehicle battery and the fuse.
RML9435 only: Check the
D+ signal on the vehicle.
Check the gas supply
(gas cylinder, gas valve).
Press the
button once the
fault is rectified.