9. CONNECT THE WIRING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
Insert the house wiring cable through the wire clamp, and tighten the wire clamp
to secure the cable. Connect the power cable to the range hood wires using
provided waterproof wire connectors. Connect BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire under GREEN ground screw. DO NOT FORGET
TO CONNECT THE GROUND.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8".
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead
smaller stranded wires slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over
torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off
excess sealant in and around conductors. DO NOT REUSE.
When reinstalling the wiring box cover, carefully insert the screws
by hand, then use a screwdriver to prevent stripping.
Reinstall wiring box cover, making sure not to pinch wires.
10. INSTALL THE BLOWER IN THE HOOD
Take the blower plate previously removed in step 4 and lay it on a protected surface.
Mount both blowers on the blower plate using 8 hexagonal nuts included with the blowers
(see illustration A). Make sure that both holes in the blower plate are entirely covered by the
blowers. The blowers should be 0.5 inch apart (see illustration B).
Reinstall the blower plate with blowers inside the hood by insert the blower plate tabs into
the slots and secure using both nuts previously removed in step 4 (see illustration C; blowers
not shown to ease understanding). Connect the blower power cord to the hood, and tie the
blower power cord using the preinstalled twist tie.
B
!
:
CAUTION
0.5"
C
HD1068A
WARNING
G
ROUND SCREW
HE0338
6
A
HO0343
HD1075
C