Mounting The Installation Plate And Drilling Holes For Piping; Mounting The Installation Plate Of The Indoor Unit - Tectro TS 1225 Manual De Instalación

Ocultar thumbs Ver también para TS 1225:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
7.

MOUNTING THE INSTALLATION PLATE AND DRILLING HOLES FOR PIPING.

7.1 Mounting the installation plate of the indoor unit.

WARNING
Use a detector before drilling the holes in the wall to detect power cables and piping in the wall
to avoid unnecessary damaging the wall and to avoid dangerous situations.
a.
Position the installation plate  level and on a sufficiently firm wall and leave a free space around
the installation plate. See Picture 8
b.
If the wall is made of bricks, concrete or a similar material, eight holes with a diameter of 5 mm have
to be drilled in the wall. Insert the plugs  for the respective mounting screws  in the wall.
c.
Mount the installation plate  on the wall with eight type "A" screws .
G
NOTE
Mount the installation plate and drill wholes in the wall according the material in which the wall
is build and the respective attachment points on the installation plate. (dimensions are in "mm"
unless indicated otherwise).
Correct mounting of the installation plate
4
76
Picture 7
Picture 8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cs 1225Ts 1232Cs 1232Ts 1248Cs 1248

Tabla de contenido