3-7/8" (9.8 cm)
Roughing-In
NOTICE: All dimensions are nominal. The stud opening tolerance is +1/4" (6 mm) and -0 (0 mm).
Carefully measure your fixture before determining enclosure size. When a fire-rated wall is specified,
dimensions are to the inside of the wall board. Some shimming between the stud frame and the fixture
may be required. Dimensions given in the roughing-in information are crucial for proper installation.
Construct the framing and plumbing accurately.
NOTE: If a firewall is required, increase the roughing-in dimensions according to the thickness of the
firewall material. Stud opening dimensions must be measured toward the exposed side of the wall
material.
NOTE: If the unit will be installed against a masonry wall, make provisions for plumbing connections.
Construct a separate frame wall a minimum of 6" (15.2 cm) from the masonry wall.
NOTE: You must install the shower receptor to an adequately supported, level subfloor.
Kohler Co.
60" (152.4 cm)
7-3/4" (19.7 cm)
1-15/16" (4.9 cm)
14-1/4"
(36.2 cm)
30"
(76.2 cm)
1-3/16"
(3 cm)
4-3/8"
(11.1 cm)
3
17˚
1069569-2-D