Dedicated Circuit
1. Provide Electrical Service
CAUTION: Risk of electrical shock. Disconnect the power
before proceeding. Refer to the "Important Safety Instructions"
section.
A Ground-Fault Circuit-Interrupter (GFCI) is recommended for
this circuit.
Local electrical codes may require that electrical work be
performed by a licensed electrician. Follow all local electrical
codes.
Refer to the roughing-in information to determine the proper
circuit location.
The sink controls and system have been prewired at the factory.
Only minor electrical connections are required during installation.
The power wiring and terminal box must be provided by the
customer.
Provide a dedicated 120 V, 15 A, 60 Hz two-wire with ground
circuit for the cook sink.
Install a junction box in the cabinet in the vicinity of the cook
sink's location. Locate the junction box away from any water or
drain piping.
Pull wires from the circuit breaker panel board through the
junction box to the cook sink area.
Terminate the wires at the circuit breaker.
Do not apply power until directed to do so.