Descargar Imprimir esta página

Flotec FP7KV Manual De Uso Y Manutención página 6

Ocultar thumbs Ver también para FP7KV:

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
Disassembly of the diffuser filter VIPVORT
Disassembly of the diffuser filter: disassemble the diffuser filter only after removing the safety screw (See Fig. 3, pos. 5).
Keep the pump motionless and turn the diffuser filter clockwise looking at the pump from the bottom. To reassemble
the diffuser filter, lubricate the O-ring with water and turn the filter counterclockwise (see Fig. 6).
Pump storage instructions
Store the pump in a dry place and protect it from frost.
PROBLEM
1) THE ELECTROPUMP DOES
NOT PUMP WATER, THE
MOTOR DOES NOT RUN
2) THE PUMP DOES NOT SUP-
PLY WATER BUT THE MOTOR
IS RUNNING
3) THE PUMP SUPPLIES A
LIMITED AMOUNT OF WATER
4) INTERMITTENT OPERATION
Only for EU countries
Do not dispose of electric tools together with household waste material!
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment
and its implementation in accordance with national law, electric tools that have reached the
end of their life must be collected separately and returned to an environmentally compatible
recycling facility.
8
POSSIBLE CAUSE
1) No electricity.
2) Plug inserted incorrectly.
3) Enabled safety switch.
4) Blocked impeller.
5) Damaged motor or condenser.
1) Obstructed suction grid.
2) Blocked check valve.
3) Air in impeller body (air bubbles).
1) Partially obstructed suction grid.
2) Obstructed pipe.
3) Worn impeller.
1) Solid particles prevent the free rotation
of the impeller.
2) The temperature of the fluid is too high.
3) Voltage out of range.
4) The fluid is too dense.
5) Faulty motor
2) Verify that voltage is present and that the
plug is correctly inserted.
3) Reset the safety switch.If the safety switch
is once more enabled, contact a specialised
electrician.
4) Remove possible obstructions from the
impeller.
5) Contact the Customer Assistance Service.
1) Clean the grid.
2) Clean or replace the valve.
3) Perform several start-ups in order to
remove all the air.
1) Clean the grid.
2) Remove the obstructions
3) Contact the Customer Assistance Service.
1) Remove the foreign particles.
3) Supply the pump in accordance with
nameplate data.
4) Dilute the pumped fluid.
5) Contact the Customer Assistance Service.
4
GB
REMEDY

Publicidad

loading

Este manual también es adecuado para:

Fp14kvxVipvort 130/5Vipvort 180/6