A 9 volt transistor radio battery (NEDA
1604) is required to power the Code
Scanner. Either a regular or alkaline
battery may be used. The Code
Scanner has an automatic battery shut-
off when not in use. There is no "power
off" switch because the unit uses no
power when the light is off and the tone
is quiet. The battery must be installed
before use.
Do the following:
1) Remove two screws from the bottom
side of the Code Scanner.
2) Separate the two halves of the Code
Scanner.
3) Insert battery:
4) Reassemble Code Scanner case
and replace screws.
Do the following:
1) Put the Hold/Test switch in TEST
position.
AUDIO
ON
OFF
2) Put the Audio switch in ON position.
3) Use a coin to touch the two side-by-
side terminals on the bottom row (the
one with three terminals) of the Code
Scanner connector.
4) Both the STO light and the tone
should turn ON. Replace battery
when the light or tone gets weak.
8
TEST
ST0
TM