3. Use a 15/16" (23.8 mm) combination wrench and channel lock
pliers to attach the flexible connector to the adapters. Check
that connector is not kinked.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/3"
[12.7 mm] male pipe thread)
D. Flexible connector
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the
"on" position.
A. Gas pressure regulator shut-off valve shown in the "on"
position
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3. Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
E. Manual gas shutoff valve
F.
1/2" (12.7 mm) or 3/4"
(19.1 mm) gas pipe
G. Use pipe-joint compound.
H. Adapter
4. Remove cooktop burner caps and bases from package
containing parts. Place the burner bases as indicated by the
following illustration for your model:
For Model WFG515S0J :
A. Medium (Semi Rapid)
B. Large (Ultra Rapid)
For Models WFG525S0J and WFG535S0J:
A. Medium (Semi Rapid)
B. Large (Ultra Rapid)
C. Oval
5. Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
A. Burner base
B. Burner cap
C. Burner grate
D. Small (Auxiliary)
E. Large (Ultra Rapid)
D. Small (Auxiliary)
E. Large (Ultra Rapid)
13