4. Drill two 1/8" (3 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Rear position
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1
mount anti-tip bracket to the wall or floor.
6. Move range close enough to opening to allow for final gas and
electrical connections. Remove shipping base, cardboard or
hardboard from under range.
7. Move range into its final location, making sure rear leveling leg
slides into anti-tip bracket.
8. Move range forward onto shipping base, cardboard or
hardboard to continue installing the range using the following
installation instructions.
12
Front position
Diagonal
(2 options)
5
/
" (4.1 cm) screws provided,
8
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14ʺ (36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with Propane gas to
all pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
A. Gas pressure regulator
B. 90° elbow (must have 1/3"
[1.2 cm] male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
Typical flexible connection
1. Apply pipe-joint compound made for use with propane gas to
the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the other
adapter to the gas shut-off valve. Tighten both adapters.
F.
Manual gas shutoff valve
G. 1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe
H. Nipple
I.
Union
J.
90° elbow