4.1
Self-controlled safety edge SOFA1-SOFA2 or GOPAVRS
Command
SOFA1-SOFA2
GOPAV
1
6
1
8
Function
SAFETY TEST
N.C.
STOP SAFETY
DEVICE
N.C.
REVERSAL
SAFETY
DEVICE
Description
Place the SOFA1-SOFA2 or GOPAVRS device into its hou-
sing for plug-in cards AUX.
Connecting terminal 41 enables a safety edge test cycle
before every operation.
If the test fails the SA led flashes and the test is repeated.
Connect the output contact of device SOFA1-SOFA2 to
terminals 1-6 on the control panel (in series with the
photocell output contact, if installed).
Connect the output contact of device SOFA1-SOFA2 to
terminals 1-8 on the control panel (in series with the
photocell output contact, if installed).
ATTENTION: for quick operation on the safety edge, con-
nect it to contact 1-6.
29