Application Example For Barriers; Application Example For Rolling Shutters - entrematic Ditec E1A Manual De Instalación

Ocultar thumbs Ver también para Ditec E1A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84

12. Application example for barriers

When control panel is used for barriers operations:
- set RF=CT-5 (MAX);
- set TM=MAX;
- set JR6=ON;
- select the proper opening direction by means of DIP2.
(Example 1). Connect opening and closing limit
switches N.C. contacts to plug 12-0-11.
(Example 2). Control N.C. 1-6 (safety stop) can
be changed into control N.O. 1-4 (closing) setting
6→4=OFF.
To have the barrier close again soon after transit
between the photocells (or other safeties con-
nected to 1-8), set DIP3=OFF.

13. Application example for rolling shutters

When the control panel is used in applications for rolling shutters:
- set JR6=ON
- connect the N.C. limit switches in succession to the motor phases
- make a jumper with the terminals 0-11-12.
NOTE: if the control panel is used in the hold to
i
run mode, disconnect terminal 9 (see example 1
in Section 14).
DIP2=OFF
ON
1
DIP2=ON
ON
1
Limit switch
39
CT
1
2
3
RF=CT-5
4
5
MAX
ON
2 3 4
1
2 3 4
R1
TC TM
12 0 11
JR6
12
11 0 1 5 6 8 9 41
2 3 4
6>4
DIP3=OFF
ON
1
2 3 4
R1
TC TM
12 0 11
JR6
12
11 0 1 5 6 8 9 41
<MAX
<MAX
ON
1
2 3 4
R1
TC TM
12 0 11
JR6
N C U W V
12
11 0 1 5 6 8 9 41
M1
1~

Publicidad

Tabla de contenido
loading

Tabla de contenido