powerswitch
®
WARNINGS
• TO AVOID FIRE, SHOCK OR DEATH, disconnect all power supplies to enclosure
before exposing interior. More than one supply disconnect may be required to
de-energize this equipment before servicing.
CAUTIONS
• For installation only by an electrician in accordance with the national electrical code
(NEC
) or the Canadian Electrical Code (CEC
®
• Separate over current protection must be provided in accordance with the NEC
article 220 or CEC
®
, Section B as appropriate.
KIT CONTENTS
CONTENU DE LA TROUSSE
CONTENIDO DEL JUEGO
Switch Activator
Actionneur de l'interrupteur
Activador del Interruptor
CAT No. AUXNO
CAT No. 005-AUXNO-NF1 – Auxiliary contact. Early Break.
CAT No. 005-AUXNO-NF1 – Contact auxiliaire. Coupure précoce.
CAT No. 005-AUXNO-NF1 – Contacto Auxiliar. ruptura prematura.
NOTE: This auxiliary contact contains both a normally open (NO) and a
normally closed (NC) contact on the same part. When installed, NC
contacts are on top and NO are on the bottom.
REMARQUE: ce contact auxiliaire est normalement ouvert d'un côté
et normalement fermé de l'autre. Quand il est installé, le
mécanisme normalement fermé est sur le dessus, et le
mécanisme normalement ouvert est sur le dessous.
NOTA: Este contacto auxiliar contiene tanto un contacto normalmente abierto
como un contacto normalmente cerrado en la misma parte. Cuando se
instala, los contactos normalmente cerrados se encuentran en la parte
superior y los contactos normalmente abiertos en la parte inferior.
3
insert.
5
Reinstall the switch. Torque screws 15 in-lbs. Close door. Torque screws 10 in-lbs.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department,
165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for one year from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for
a particular purpose, is limited to one year. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Auxiliary Contacts
For use with 100A Non-Fused Disconnect Switches
Cat. No. AUXNO-NF1
10A-600VAC Max.
) local codes.
®
®
INSTALLATION
WARNING: TO AVOID FIRE, SHOCK OR DEATH, disconnect all power supplies to enclosure before exposing interior.
More than one supply disconnect may be required to de-energize this equipment before servicing.
1
Open door.
Non-Metallic boxes
Boîtes non métalliques
Cajas No Metálicas
4
Assemble.
Non-Fused Disconnect Switch
le sectionneur sans fusible
el Interruptor de Desconexión Sin Fusible
LIMITED 1 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
CAUTIONS
• Use this device with copper or copper clad wire only.
• Ensure that the rating marked on the device is correct for the intended installation.
This device is suitable for use on a circuit capable of delivering not more than
65,000 RMS symmetrical amperes, 600 VAC maximum when protected by 100 A
class J fuses.
• The enclosure cover cannot be removed when the handle is in the "on" position.
• Always remove the switch from the enclosure when attaching or replacing all
auxiliary contacts.
Metallic boxes
Boîtes métalliques
Cajas Metálicas
Aux Contact
Contact auxiliaire
ContactoAuxiliar
PK-A3265-10-02-4A
ENGLISH
Remove Non-Fused Disconnect
2
Switch.
Screws
Vis
Tornillos
Pull Down
Tension Spring
Tirer le ressort
de tension
vers le bas
Jale hacia
abajo el
resorte de
tensión
Normally Closed Contacts
contacts normalement fermés
contactos normalmente cerrados
b
Normally Open
Contacts
contacts normalement
ouverts
a
contactos normalmente
abiertos

Publicidad

loading

Resumen de contenidos para Leviton powerswitch AUXNO-NF1

  • Página 1 LIMITED 1 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for one year from the purchase date.