General; Safety; Maintenance And Monitoring; Use Original Parts - CEMO CENTRI SP 30 Manual Del Usuario

Ocultar thumbs Ver también para CENTRI SP 30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB

1. General

1.1 Safety

The pump is state of the art technology and complies
with approved technical safety regulations.
Each piece of equipment is tested for function and
safety before despatch.
The pump is safe to operate when used correctly.
Incorrect operation or misuse poses a dangerous risk to:
• the operator's health
• assets
• the environment
The pump must be used only if it is in defect-free
technical condition and is the version delivered
by the manufacturer.
On safety grounds, it is not permitted to make modifica-
tions (except for the addition of manufacturer accessori-
es), dismantle parts or open the housing.
Make sure that:
• you understand all the safety notices,
• the operator is informed about the notices and
understands them,
• the operating instructions are accessible.

1.1.1 Maintenance and monitoring

The pump must be regularly checked to ensure it is in a
safe condition, in particular:
• sight checks for leaks
• function test
• inspection according to maintenance plan
(see section 9).

1.1.2 Use original parts

Please only use original parts provided or recommend-
ed by the manufacturer. Also take note of all safety and
usage information provided with these parts.
This applies to:
• parts for accessories

1.1.3 Using/maintaining the pump

To prevent danger, all persons involved with commis-
sioning operation, maintenance and servicing must:
• be suitably qualified,
• read these instructions thoroughly
• be assigned to operate the equipment,
• comply with the relevant safety at work regulations.
Warning!
Risk of injury when delivering liquids dangerous to
health (burning, poisoning etc.). Follow the safety data
sheet for the delivery medium. Wear suitable protective
clothing (eye protection, hand protection, breathing pro-
tection etc.) if there is any risk of contact.
12
Warning!
Possible environmental and material damage from leak-
ing delivery medium (leaks or improper use). If liquid
appears on the spigot, repair this immediately with a
suitable binding agent and according to instructions.

1.1.4 Residual risk

Warning!
Risk of injury from unexpected fluid leaks. The pump
has no safety switch to prevent it from restarting inde-
pendently after a power interruption. In the event of a
power loss, turn the pump OFF at the switch and turn it
ON again manually only when power is restored.

1.2 Correct usage

The centrifugal pump with D/C motor is intended for the
delivery of the following liquids under the operating con-
ditions specified at paragraph 3.3:
Liquids with a flashpoint of > 55 °C and a viscosity
of < 20 cSt, e.g.
- Diesel fuel
- Biodiesel
- EL heating oil
- Aqueous urea solution AUS 32 (AdBlue
- Water
The equipment is not intended for any other or
additional purpose.
i

Important!

Correct usage also includes compliance with all infor-
mation in these operating instructions.

1.3 Improper usage

Operation with liquids other than those specified is
improper usage, e.g.: Bioethanol, chemicals, oils
(lubricating, hydraulic, plant oils), petrol.
Risk of explosion!
Non explosion-proof pump motor – risk of serious injury
or death when operating in explosive atmospheres.
Do not use pump in environmental conditions where
there is a risk of explosion.
)
®

Publicidad

Tabla de contenido
loading

Tabla de contenido