Hydraulic Connections; Using The Equipment For The First Time; Operation - CEMO CENTRI SP 30 Manual Del Usuario

Ocultar thumbs Ver también para CENTRI SP 30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6. Hydraulic connections

Delivery hose:
Recommended nominal diameter:
Recommended nominal pressure:
Use a suitable hose clip to secure the delivery hose
on the hose sleeve.

7. Using the equipment for the first time

Make sure that there is enough liquid in the container.
Warning!
Possible environmental and material damage from
leaking delivery medium. Ensure that the pump and
accessories are in good working condition (no leaks!).
1. The ON/OFF switch must be at "O".
2. Ensure that the delivery line is initially closed and
that the end is definitely in the container to be filled.
3. Make sure that the pump is immersed in the liquid.
4. Switch on the power source (see section 5).
5. Set the switch to "I"  pump ON
(motor should now be running).
6. Open the delivery nozzle
or the delivery line  suction begins.
Important!
Running the pump dry may damage it. If the pump is
not sucking, under no circumstances should you leave
it running dry for more than ten seconds.
7. Note whether liquid starts to come out of the pressure
line after a while, which then pushes out the air.

8. Operation

¾" (DN 19)
minimum 6 bar
Possible environmental and material damage from leak-
ing delivery medium. If liquid appears on the spigot,
repair this immediately with a suitable binding agent and
according to instructions.
1. Make sure that there is enough liquid in the container.
2. When using a flexible hose, secure the ends to the
3. The pressure side valve (delivering nozzle or
4. Set switch to "I"  pump ON
Extended use with a closed delivery line (bypass mode),
may cause overheating and damage the pump.
Run the pump with the delivery nozzle closed for brief
periods only (2-3 minutes at the most).
5. Open the valve in the delivery line so that the end of
Close the pressure side valve if the tapping
procedure is interrupted or stopped.
The tank is empty when no more liquid comes from the
end of the hose or delivery nozzle and the speed of the
pump is audibly higher.
Running the pump dry may damage it. If the pump
stops delivering, under no circumstances should you
leave it running dry for more than thirty seconds.
6. Switch off the pump (switch to "O") when the tapping
Never switch off the pump by unplugging the terminal
clamps or pulling out the mains plug.
Risk of burning from hot surfaces, and possible
pump damage from overheating. Running cycles of
> 10 minutes can cause the motor temperature to
rise. After each running cycle of maximum 10 minutes
always allow the same length of time for the switched
off motor to cool down.
Warning!
tank to be filled. If no suitable connections are avail-
able, make sure you are holding the delivery hose
tightly before you begin filling.
system valve) must be closed to begin with.
(motor should now be running).
Important!
the hose or the delivery nozzle can be well secured.
Warning!
procedure is complete.
i
Important!
Warning!
GB
15

Publicidad

Tabla de contenido
loading

Tabla de contenido