Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
NOTE: This range hood is recommended for use with cooking
surfaces according to the following:
36" (91.4 cm) or 48" (122 cm) range hoods with 1 motor
(585 CFM) to be paired with maximum total rating of
90,000 BTU.
36" (91.4 cm) or 48" (122 cm) range hoods with 2 motors
(1170 CFM) to be paired with maximum total rating of
105,000 BTU.
Tools needed
■
Level
■
Drill
■
1
1
/
" (3 cm) drill bit
4
■
3/32" (2.4 mm) drill bit if installing into wood
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
Scissors
Parts needed
■
Home power supply cable
■
1/2" (1.3 cm) UL listed or CSA approved strain relief
■
Three UL listed wire connectors
■
One wall or roof cap
■
Metal vent system
■
Two 175 W max heat lamp bulbs
■
Blower motor system—internal or external
Parts supplied
Remove parts from packages. Check that all parts are included.
■
Two metal grease fi lters for 36" (91.4 cm) models
Three metal grease fi lters for 48" (121.9 cm) models
■
Two vent cover support brackets
■
Two 4.5 x 13 mm screws
■
Two 10 x 50 mm mounting screws
■
Two 8 x 40 mm mounting screws
■
Two D5.3 x 20 mm washers
■
Four 5 x 45 mm screws
■
Six 4.2 x 8 mm screws
■
T-20
®
TORX
®†
adapter
†TORX
®
and T20
®
are registered trademarks of Acument Intellectual Properties, LLC.
4
INSTALLATION REQUIREMENTS
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualifi ed technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specifi ed on the model/serial rating plate. The model/serial rating
plate is located inside the range hood on the rear wall of the
range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
The range hood is factory set for venting through the roof or
through the wall.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with
local codes.
Product Dimensions
Vented Installations
11
/
" (28.7 cm)
5
16
22
/
" (57.8 cm)
3
4
36" (91.4 cm)
or 48" (121.9 cm)
24½" (62.3 cm) min.
327⁄16" (82.4 cm) max.
7
/
" (20.0 cm)
7
8
25" 63.5 cm)