CLEANING AND MAINTENANCE

NOTE: Grease all o-rings for easier assembly.
Hose adapter fitting is glued permanently into
the valve body.

FILTER CLEANING

1.
Unscrew the filter holder using a screwdriver or coin.
Pull out filter holder. (See Figure 3)
2. Remove filter screen/spring assembly.
Clean with compressed air or replace if damaged.
(See Figure 4)
VALVE TIMING ADJUSTMENT
1. Gas valve opening is adjusted by the
adjustment screw. (See Figure 5)
2. It should be set so the valve opens when the gas
handle is depressed half way.
REPLACE IGNITER
1.
Remove 5 mounting screws and remove right side of
housing. (See Figure 6)
2. Remove retaining screw holding the cable and the
contact spring. (See Figure 7)
3. Use a screwdriver to snap off the clamp.
(See Figure 8)