IMPORTANT SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce
the risk of fire, electrical shock and injury to persons, including the following:
Read all instructions before using this Fan.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR PERSONAL INJURY, ALWAYS
FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS:
DO NOT use this fan to ventilate areas where flammable liquids or vapors are used, stored or are present, including paints,
gasoline, varnishes, floor refinishing products or solvents. ALWAYS read and follow all warnings and instructions on the con-
tainers for these products!
ALWAYS be sure the plug fits tightly into the outlet. When plugs fit loosely into outlets, they may slip partially out of the outlet
and create a poor connection. This may cause outlets to overheat and create a potential fire hazard. Outlets in this condition
should be replaced by a qualified electrician.
ALWAYS unplug the power cord when servicing, cleaning or moving the Fan. DO NOT use the ON/OFF switch as the sole means
of disconnecting power. NEVER leave children unattended when the Fan is on or plugged in. ALWAYS turn off and unplug the Fan
when not in use.
BE CERTAIN that the power source for the Fan is 120V AC. DO NOT plug the Fan into 240V or other power source.
The Blue Plug™ on your AirKing fan is a safety feature. It contains a non-replaceable safety device (fuse) that should not be removed
or tampered with. To reduce the risk of fire, electric shock and personal injury, DO NOT attempt to remove, replace, repair or tamper
with the originally supplied plug. If the Fan has stopped functioning, it may be due to the safety device incorporated in this plug.
The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no
circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and
all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only.
DO NOT USE A THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE THE RISK OF ELEC-
TRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
CAUTION
• AVOID the use of extension cords, power strips, power taps, outlet style air fresheners or other cord connected device, as these
devices may overheat and cause a fire hazard.
•DO NOT route power cord under rugs, carpets, runners or furniture. This may damage the cord or cause it to overheat creating a fire hazard.
•ALWAYS place the Fan on a stable, flat, level surface while in operation to prevent the Fan from overturning.
•NEVER insert or allow fingers or objects to enter grill openings while Fan is in operation or injury and/or damage to the Fan may occur.
•DO NOT block, cover or obstruct air flow to or from the fan while in operation.
•DO NOT use this Fan outdoors or near water or wet locations such as a bath tub, pool or hot tub. Use of this Fan in a wet location
may create a shock hazard.
•DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture
or appliances. Arrange cord away from traffic area and where it will not be tripped over.
•NEVER use a single extension cord to operate more than one Fan or other electrical device.
•DO NOT use this Fan if it has been damaged or is not functioning properly.
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).This Fan is not suitable for use in agricultural
facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article
547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for agricultural buildings.
•THIS FAN DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).This Fan is not suitable for use in hazardous
locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical
requirements for hazardous locations.
SAVE THESE INSTRUCTIONS
Rev. M 4/17
2
MODELO 4DA35B/9102B 4DA36B/9106B
DESCRIPCIÓN
Los Ventiladores Oscilantes Air King
®
cm) vienen equipados con un motor de funcionamiento silencioso y
una hélice de tres aspas. El ventilador es potenciado por un motor
capacitador de hendidura permanente y prelubricado con un cable
eléctrico 18/3 de 6 pies (1.8 m) de largo. Las parrillas del ventilador
cumplen con los requisitos de OSHA. Equipo aprobado por ETL.
ESPECIFICACIONES
Motor .........................................120V, 60Hz (12")(30,5 cm)
...................................................120V, 60Hz (16")(40,6 cm)
Tamaño de paletas .....................
12" (30,5 cm) Modelo (4DA35B/9102B)
...................................................
16"(40,6 cm) Modelo (4DA36B/9106B)
Velocidades ..............................3 velocidades
Control ......................................Perilla Rotatoria
Distribución del flujo de aire ....90˚
MODELO
4DA35B/9102B
VELOCIDAD ALTA MEDIA BAJA ALTA MEDIA BAJA
CFM
930
780
620
M
3
/s
0.43
0.37
0.29 0.80
RPM
1450
1300
1090 1545
Amps
0.40
0.30
0.27 0.71
Watts
39
35
32
dB A
45
41
36
ENSAMBLADO
1. Incline el cabezal del ventilador hacia atrás. Coloque la Parrilla
Plástica Posterior en el Motor. (Figura 1)
2. Alinee el corte triangular en "∆" en la Parrilla Plástica Posterior
con el poste triangular en la parte superior de la cubierta frontal
del Motor. Encaje totalmente la Parrilla Plástica Posterior y
fíjela con la Tuerca de Plástico, haciéndola girar en el Sentido
de las Manecillas del Reloj. (Figura 2)
3. Deslice la Hélice sobre el Eje del Motor. (Alinee la Ranura en
el bloque de la hélice con la Clavija del eje del motor.) (Figura
3)
4. Para fijar la Hélice, atornille el Girador en el Eje en el
Sentido Contrario a las Manecillas del Reloj hasta que
se encuentre fija en el cubo de la hélice.
5. Con el cabezal del ventilador en posición recta, alinee el
Ornamento de la Parrilla Anterior para que quede en posición
horizontal. Inserte la parte inferior de la Parrilla Anterior dentro de
la Parrilla Plástica Posterior. La Lengüeta en la parte inferior de
la Parrilla Plástica Posterior debería encajar entre los rayos de la
Parrilla Anterior. Encaje la Parrilla Anterior dentro de la Parrilla
Plástica Posterior comenzando desde arriba y progresando en
forma descendiente por ambos lados.
Hélice
Parrilla
Parrilla
Posterior
Posterior
Girador
Tuerca de
Plástico
Parrilla
Anterior
Figura 2
Figura 1
Ranura
2084067
Rev. M 4/17
FUNCIONAMIENTO
de 12" (30,5 cm) y 16" (40,6
OSCILACIÓN VARIABLE: Jale la perilla de oscilación ubicada en la
parte posterior del motor hacia arriba. Gire el cabezal del ventilador
hacia la izquierda, derecha o hacia delante. Empuje la perilla de
oscilación hacia abajo y el ventilador oscilará describiendo el ángulo fijado.
ÁNGULO VERTICAL: Para ajustar el ángulo vertical, incline el cabezal
del ventilador hacia arriba o abajo, según prefiera.
VELOCIDAD: La velocidad está controlada por una perilla rotatoria:
(0) Apagado, (3) Alta, (2) Media, (1) Baja.
CABLE ELÉCTRICO: Enchufe el cable eléctrico en un tomacorriente
de pared (CA 120 Voltios, 60 Hz).
MANTENIMIENTO
ADVERTENCIA:
SIEMPRE DESENCHUFE EL CABLE ANTES
DE MOVER O DAR SERVICIO AL VENTILADOR.
ADVERTENCIA:
¡NO SUMERJA EL VENTILADOR EN AGUA!
LIMPIEZA: Utilice un paño suave humedecido con una solución
jabonosa liviana, tal como un detergente líquido para lavar platos.
4DA36B/9106B
Seque TODAS LAS PARTES POR COMPLETO antes de rearmar.
Después de dar mantenimiento o servicio, REARME POR COMPLETO
la unidad en la forma descrita en este manual de instrucciones,
1710
1500
1330
antes de volver a conectarla a la fuente de poder.
0.71
0.63
PRECAUCIÓN:
No utilice gasolina, bencina, acetona,
1394
1244
limpiadores abrasivos, etc. puesto que dañarán el Ventilador.
0.54
0.48
NUNCA use ALCOHOL O SOLVENTES.
77
65
57
LUBRICACIÓN: Los cojinetes de precisión vienen sellados de por
53
49
44
vida en la fábrica y no precisarán ninguna lubricación adicional.
ALMACENAMIENTO: Guarde el Ventilador con estas instrucciones
en un lugar fresco y seco.
REPARACIONES: Cualesquiera otras reparaciones, con la
excepción del mantenimiento general a cargo del usuario, deben
ser realizadas por un representante de servicio autorizado.
Clavija
Motor
Figura 3
Espiga
Figura 3