6.1.3
and
Lock / Unlock the display:
Hold
and
Water temperature setting:
Press
or
Parameter checking:
Press
first, then press
Code
d0
IPM mould temperature
d1
Inlet water temp.
d2
Outlet water temp.
d3
Ambient temp.
d4
Frequency limitation code
d5
Piping temp.
d6
Gas discharge temperature
d7
Step of EEV
d8
Compressor running frequency
d9
Compressor current
d10
Current fan speed
d11
Error code for last time
Remark: d4: Frequency limitation code,
1: Coil pipe temperature limit,
4: Drive Current frequency limit,
16: Drive high temperature frequency limit.
Press
first, then press
If needed, press
(for example: Press
or
to adjust the parameter P7 Inlet water temp. Correction, to confirm press
Code
Name
P0
Mandatory defrosting
P1
Working mode
P2
Timer on/off
button
for 5 seconds to lock/unlock the display.
to set the water temperature directly.
to check the " User parameter from d0 to d11
Condition
8: Drive voltage frequency limit,
to check/adjust the User parameter from P0 to P7
second, then press
first, then press
Scope
0-1
0-1
0-1
Scope
0-120℃
-9℃~99℃
-9℃~99℃
-30℃~70℃
0,1,2,4,8,16
-30℃~70℃
0℃~C5℃ (125℃)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error code
0: No frequency limit,
2: Overheating or overcooling frequency limit,
or
to adjust the current parameter.
to enter parameter P7 checking, and press
Defaul
t
0: Default normal operation
0
1: Mandatory defrosting.
1
1:Heating mode, 0:cooling mode,
0
1: Timer on/off starts, 0: Timer on/off is out of work
(The setting of P5 and P6 won't work)
20
Remark
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
N*5
Real testing value
Real testing value
Real testing value
second, then press
.)
Remark

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido