P3=0,
Cooling
T1≤Tset+0.5℃,
mode
last for 30
minutes
Option 2; P3=1 Filtration pump is always on, P2=0 the timer function is no active
Under condition P3=1, whenT1≥Tset+1℃(T1≥29℃) last for 3 minutes, heat pump will be in standby, while filtration
pump is always on.
Under option 2, with activation of the timer; P2=1 to start and stop the filtration pump according the programming
of the P4 (time), P5 (timer ON) and P6 (timer OFF)
Condition for the heat pump start, timer ON actives;
When the timer reaches the set time of TIMER ON, the filtration pump will start and after 5 minutes the heat pump
start. The heat pump stays in stop if the water in temperature is ≥ Tset+1℃, before the TIMER OFF, the filtration is
still activated.
Condition to stop the heat pump, timer OFF actives;
When the timer reaches the set time of the TIMER OFF, the heat pump will stop and after 5 minutes the filtration
pump stops.
NB; Symbol of automatic TIMER start
stop
, the light will be on when it is in operation. Outside the time operation the display will be advise by OFF.
If heat pump is turned ON/OFF manually, the filtration pump will start and stop accordingly.
NOTE :
Tset = Tseting water temperature
For example : Tset = 28℃ Tseting water temperature in your pool heat pump
Tset-0.5 = less 0.5℃ than Tseting temperature, Tset- 0.5 = 28-0.5=27.5℃
Tset+0.5= more 1℃ than Tseting temperature, Tset+ 0.5 = 28+0.5=28.5℃
6.5 Protection of the unit
Remarks:
1. In heating mode, if the water out temperature is higher than the set temperature over 7℃, LED
controller displays EE04 for water over-heating protection.
In cooling mode, if the water out temperature is lower than the set temperature over 7℃, LED controller
2.
displays PP11 for water over-cooling protection.
P3=0,
1. Then it enters into
standby mode for 1 hour
T1≤28.5℃,
(It will not restart except
last for 30
turn it on manually.)
minutes
, the light will be on when it is in operation, symbol of automatic TIMER
2. After 1 hour, the filtration
pump will restart for 5 minutes. If
it tests T1≥29℃, the heat pump
will start to work until T1≤28.5℃
and last for 30 minutes to go into
standby
24