Checking the vertical line
Fix a plumb bob with a line at least 2.5 m in length on the
wall, making sure that the bob can swing freely. Switch on the
laser, direct the lines at the plumb and align the bubble levels (2).
The precision is within tolerance if the deviation between the
laser line and plumb line is not greater than 0.5 mm / m.
Calibration
The measuring device should be calibrated and tested on
a regular basis to ensure it is accurate and working properly.
We recommend the measuring device is calibrated every
1 - 2 years. If necessary, contact your distributor or the
UMAREX-LASERLINER service department.
Information on maintenance and care
Clean all components with a damp cloth and do not use
cleaning agents, scouring agents and solvents. Remove
the battery(ies) before storing for longer periods. Store
the device in a clean and dry place.
Technical data
Angle accuracy
Levelling
Visibility (typical)*
Laser wavelength
Laserklasse
Power supply
Operating time
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight
* at max. 300 lux
10
EN
(Subject to technical changes without notice. 19W48)
± 0.5 mm / m
manual
10 m
515 nm
2 / < 1 mW
(EN 60825-1:2014/AC:2017)
2 x 1.5V LR6 (AA)
approx. 3 hours
0°C ... 50°C, max. humidity
80% rH, no condensation,
max. working altitude 4000 m
above sea level
-10°C ... 70°C,
max. humidity 80% rH
200 x 48 x 100 mm
350 g (incl. batteries)