SAFETY GUIDELINES / DEFINITIONS
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION: Used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in property
damage.
RISK OF UNSAFE OPERATION. When using tools or equipment, basic safety precautions should always be followed to reduce the risk
of personal injury. Improper operation, maintenance or modification of tools or equipment could result in serious injury and property
damage. There are certain applications for which tools and equipment are designed. Manufacturer strongly recommends that this product
NOT be modified and/or used for any application other than for which it was designed. Read and understand all warnings and operating
instructions before using any tool or equipment.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: This product or its power cord contains lead, a chemical known to the State of California to cause cancer and birth defect
or other reproductive harm. Wash hands after handling.
READ ALL INSTRUCTIONS
WARNING: Read all instructions before operating the air compressor. Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
GENERAL SAFETY WARNINGS AND INSTRUCTIONS
• This product is intended for household, consumer use only.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, BURST HAZARD, OR INJURY TO PERSONS OR PROPERTY:
• Avoid dangerous environments. Don't use this unit in damp or wet locations. Never submerge this unit in water; do not expose it to
rain or snow, or use when wet.
• Keep children away. All visitors should be kept at a distance from work area.
• Store idle unit indoors. When not in use, this unit should be stored indoors in a dry, and high or locked-up place – out of the reach of
children.
• Disconnect the unit. Disconnect the unit from the power supply when not in use and when charging.
• Use of accessories and attachments. The use of any accessory or attachment not recommended for use with this unit could be
hazardous. Refer to the accessory section of this manual for further details.
• Stay alert. Use common sense. Do not operate this unit when you are tired or impaired.
• Check for damaged parts. Any part that is damaged should be replaced by the manufacturer before further use. Contact the
manufacturer at (877) 571-2391 for more information.
• Do not operate this unit near flammable liquids or in gaseous or explosive atmospheres. Motors in these tools normally spark,
and the sparks might ignite fumes.
• Never cover unit while it is operating.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:
• Do not put the unit in water or other liquid. Do not place or store this unit where it can fall or be pulled into water or become wet.
• Charge indoors only. Do not expose charger to water or any other liquid.
• Do not clean this unit with a water spray or the like.
• Use only the adapters supplied with this unit to charge the unit.
• When an extension cord is used:
– The marked rating of the extension cord should be at least as great as the electrical rating of this unit.
– The cord should be arranged so that it will not drape over the countertop or tabletop where it can be tripped over, snagged, or
pulled on unintentionally (especially by children).
– The extension cord should be kept dry and off the ground.
• Disconnect the unit from any power source before attempting maintenance or cleaning. Turning off controls without disconnecting will
not reduce this risk.
• When charging the unit using an external DC power source, make sure the voltage is rated at 12 volts DC. The unit will not operate
from a 6 volt power source and will sustain permanent damage if connected to a 24 volt power source.
• NEVER connect this unit to a positive grounded vehicle using the 12V DC Charging Adapter
SPECIFIC SAFETY INSTRUCTIONS FOR CHARGING THIS UNIT
• IMPORTANT: This unit is delivered in a partially charged state. Fully charge the unit before using it for the first time using the supplied
AC Charging Adapter for a full 10 hours or until the battery icon shows 4 solid bars.
• All functions should be turned off when the unit is charging or not in use. Make sure that all functions are turned off before connection
to a power source.
HRC120DS_ManualENSP_082517.indd 4-5
4
4
CAUTION – TO REDUCE THE RISK OF PROPERTY DAMAGE: Pull by connector rather than cord when disconnecting the 120V AC
Charging Adapter from an AC outlet.
WARNING: The 12V DC Charging Adapter is intended for charging the unit battery only; attempting to use the 12V DC
Charging Adapter as power source for the unit may cause it to overheat, causing property damage and injury to persons.
WARNING: Never attempt to use the AC and DC charging methods at the same time.
SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS
WARNING – BURST HAZARD:
• Carefully follow instructions on articles to be inflated.
• Never exceed recommended pressures. Bursting articles can cause serious injury.
• Always monitor the pressure on the LCD screen.
CAUTION – TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• Never leave the compressor unattended while in use.
• Do not operate the compressor at pressures greater than 120 PSI; and do not operate the compressor continuously at 120 PSI for longer
than approximately 3 minutes. Follow the instructions in the "Using the Portable Compressor" section.
SAVE THESE INSTRUCTIONS
INTRODUCTION
Congratulations on purchasing your new
Stanley
AirPro 120
®
this Instruction Manual and follow the instructions carefully before using this unit.
CHARGING/RECHARGING
Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from self-discharge
over time and more rapidly at higher temperatures. Therefore, batteries need periodic charging to replace energy lost through self-
discharge. When the unit is not in frequent use, manufacturer recommends the battery be recharged at least every 30 days.
Before each use, check the unit's battery status on the LCD Screen:
• Four solid bars on the battery icon indicate a full battery. The unit is ready to use.
• Only one or two solid bars on the battery icon indicates that the unit's battery charge level is low. In this case, the battery SHOULD be
recharged before use or the built-in low-voltage protection may activate (the empty battery icon will flash for a short period before
automatic shut-down). If the unit shuts down, it MUST be recharged immediately.
• An empty battery icon indicates the battery MUST be recharged immediately.
Notes:
This unit is delivered in a partially charged state – you must fully charge it upon purchase and before using it for the first time. Initial AC charge should
be for 10 hours or until the battery icon shows 4 solid bars.
Recharging the battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery
life. The battery must be recharged using the 120V AC Charging Adapter.
Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.
The time required to fully recharge the built-in battery depends on the charge status after use. Approximate recharging time is 10 hours.
CAUTION: RISK OF PROPERTY DAMAGE:
• Failure to keep the battery charged will cause permanent damage and may result in poor performance.
• Overcharging will reduce battery life. Do not overcharge:
– Never charge for longer than 10 hours using the 120V AC Charging Adapter.
– Never charge for longer than 5 hours using the 12V DC Charging Adapter.
Charging the Unit Using the 120V AC Charging Adapter (recommended)
IMPORTANT: The unit cannot be operated while charging using the AC Charging Adapter.
1. Make sure the 12V DC Charging Adapter is disconnected.
2. Insert the barrel connector of the 120V AC Charging Adapter into the 120V AC Charging Port on the back of the unit. Plug the 120V
AC Charging Adapter into a (powered) standard North American 120 volt 60Hz outlet. When the unit is properly connected to an AC
power source, the LCD Screen will display the following:
The bars on the Battery Icon represent the charge level of the unit's internal battery. The bars on the Battery Icon will change from
empty to solid (from bottom to top) repeatedly to indicate that the unit is charging. The backlight will turn on for 10 seconds (only).
3. Charge for approximately 10 hours or until the battery icon shows 4 solid bars. Do not overcharge.
4. Disconnect the AC Charging Adapter from the unit and the 120V AC power source when not in use.
Cordless Rechargable Digital Air Compressor with Digital Gauge
®
5
5
8/25/2017 3:51:51 PM
. Read