Liquid cooled ACU 410-53 size 7 devices reach rated power of up
to 200 kW. Coolant temperature for liquid cooling: see "Operating
Instructions Liquid Cooling Supplemental"
8.10 Size 8 general technical data
GB
Type
ACU410/510/610
Size
Output, motor side
Rotary field frequency
Recommended motor
shaft power
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Coolant air temperature
114
f
Hz
±500 (Depending on switching frequency)
P
kW
160
HxWxD mm
m
kg
120
A
mm
2
T
°C
n
Quick Start Guide ACU
-51
-53
-55
8
200
250
315
1067 x 439 x 375
120
120
140
up to 2 x 240
-25 ... 45 (3K3 DIN IEC 60721-3-3)
-57
-59
-61
355
400
140
140
10/18