Agri-TR
Insufficient grain quantity [Measured TW <75% of nominal TW (in
kg/hl)]
Start again test with 1 litre of grain. If problem remains, contact
your agent.
Anomaly detected on weight measurement [empty cell weight out
of range (-500g<Tare<500g)]
Contact your agent.
Not managed.
Trap problem
Check if grains or any visible object prevents the inlet trap to
close ; if problem remains, contact your agent.
Not managed.
Measuring not possible, excessive grain moisture.
Run a test with different grain. If problem remains, contact your
agent.
Ambient temperature out of range.
If ambient temperature is however in the range 2 -45 °C, contact
your agent.
Gain temperature out of range.
If grain temperature is however in the range 2 -45 °C, contact
your agent.
Temperature difference out of range (> 20°C).
Start again test with grain at ambient temperature. If problem
remains, contact your agent.
Moisture result out of range.
Start again test with different grain. If problem remains, contact
your agent.
Not managed.
No response from measure microcontroller.
Contact your agent.
Motor 1 problem (hopper trap).
Contact your agent.
Motor 2 problem (cell traps).
Contact your agent.