Install the Strike Expander Jamb
Strike Jamb
Wall Jamb
View from Inside Shower
12. Install the Strike Expander Jamb
Position the expander jamb in the strike jamb.
Align the holes in the expander jamb with the slots in the strike jamb.
Plumb the expander jamb with a level.
Secure with three #10-16 x 3/8" panhead screws.
13. Install the Fixed Panel
Slide the U-Channel approximately 3/16" (5 mm) into the pivot jamb.
Apply a bead of caulk into the entire length of the groove in the pivot jamb.
Apply a bead of caulk in the U-Channel.
NOTE: The fixed glass panel is the narrow panel.
IMPORTANT! The textured side of the glass should be positioned to the outside of the shower.
Carefully lift the narrow fixed glass panel into the outer channel in the top track and the U-Channel
at the bottom.
Press the fixed panel gently into the groove in the pivot jamb.
Sterling
Expander
Jamb
#10-16 x 3/8"
Panhead Screw
Install the Fixed Glass
Fixed Panel
13
Sealant
U-Channel
Sealant
Inside of Shower
1034026-2-D