PIR Sensitivity:
MW Sensititvity
Anti-Mask
Supervision Time:
LED:
Operation Mode:
Disposition Sensor:
* Default
** In maximum sensitivity sway recognition is disabled to achieve optimum sensitivity
NOTE: The Disposition Sensor sends an alarm following change in the position of the detector.
Camera Detector Configuration via RISCO Configuration
Software
Configure the camera settings through the RISCO Configuration Software (right-click on the Serial
Code field in the Zones node screen and in the displayed pop-up click Additional..) or through the
panel quick key programming sequence as follows (default in bold):
Programming > 2) Radio Devices > 2) Modification > 1) Zone [Select (1–32)] > 1) Parameters > 6)
Advanced 5) Camera Parameters:
Images at Alarm:
Image Interval:
Pre-Alarm Image: Yes (Yes, No) (Image capture upon each arm)
Image Resolution: QVGA (QVGA 320X240 or VGA 640X480)
Image Quality:
Color Image:
Applicable to RWX350DC model
High/Low*
Min. 25%, 50%, 65%*, 85%, max. **
Yes/No*
0-255 minutes (15 min*)
On*/Off
Walk Test: The detector transmits after each detection
Normal*
Enable/Disable*
3 (1 to 7 images)
0.5 sec (0.5, 1, 2 seconds)
High (High, Low)
Color (Color or B&W)
10