Moisture In Compressed Air; Drain Tank - Campbell Hausfeld FP2048 Instrucciones De Operacion Y Lista De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Oilless Compressors
Maintenance
Disconnect power
source then release all
pressure from the system
before attempting to install,
service, relocate or perform any
maintenance.
The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
compressor is used.

DRAIN TANK

With compressor shut off and pressure
released, drain moisture from tank by
opening drain valve underneath tank.
Figure 4
CLEANING
Turn power OFF and clean dust and dirt
from pump cover, tank, and air lines.
IMPORTANT: Unit should be located as
far from spraying area as hose will allow
to prevent over-spray from clogging air
filter.
www.chpower.com

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an
air compressor pump. When humidity is high or when a compressor is in
continuous use for an extended period of time, this moisture will collect in
the tank. When using a paint spray or sandblast gun, this water will be carried
from the tank through the hose, and out of the gun as droplets mixed with
the spray material.
IMPORTANT: This condensation will cause water spots in a paint job,
especially when spraying other than water based paints. If sandblasting, it
will cause the sand to cake and clog the gun, rendering it ineffective. A filter
in the air line (MP3105), located as near to the gun as possible, will help
eliminate this moisture.
LUBRICATION
This is an oilless type compressor
requiring no lubrication.
THERMAL OVERLOAD PROTECTOR
This compressor
is equipped with
a thermal overload protector which
will shut off motor if it becomes
overheated.
If thermal overload protector shuts
motor OFF frequently, make sure that
the compressor is used in a clean, well-
ventilated area where temperature will
not exceed 100° F.
If the thermal
overload
protector is actuated, the motor
must be allowed to cool down
before start-up is possible. The
motor will automatically restart
without warning if left plugged
into electrical outlet and unit is
turned on.
4
STORAGE
1. Drain tank of moisture.
2. When not in use, store compressor
in a cool dry place.
3. Disconnect hose and hang open
ends down to allow any moisture to
drain.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fp2049

Tabla de contenido