5. Electrical termination

Only qualified electrical personnel may
install and start up the QPD components.
For correct electrical termination please
follow the
Phoenix user manual, Appendix 1 in the
end of this document.
Below is an excerpt of the Phoenix user
manual describing the main points of the
procedure.
Please note that the dust caps mounted
on the light connector sockets are not IP
rated and will not protect against water
intrusion.
Cable termination
Cable diameter: Ø9-16mm
Wire cross section: 1.0mm
Wire diameter incl. insulation:
2.0mm to 3.80mm.
Connections
1. Strip approx. 60mm off the cable.
2. Loop the PE conductor around the
live conductors (1). As a result, the
PE conductor will be pulled out of the
terminal block last if strong tension is
exterted on the cable.
3. Insert the cable into the terminal nut.
4. Fix the wires in the conductor support
of the splice body (2).
5. Cut off the wires with a diagonal cutter
flush on the splice body (3).
6. When connecting the terminal nut to
the light connector socket, make sure
that their markings are aligned.
7. Screw the terminal nut together with
the light connector socket (4). For this,
we recommend using either the socket
wrench, a wrench, or a plier. Screw the
terminal nut as far as it goes, or with
the specified torque. It must not be
possible to unscrew the terminal again
by hand.
8. Seal off any non-allocated connections
using a protective cap.
to 2.5mm
.
2
2
Photos courtesy of Phoenix Contact GmbH.
Ground bounding screw
The decklight is equipped with a Ø4,2 hole
in each end. This can be used as grounding
where national or company regulations
require it.