Brita PURITY C Serie Manual página 25

Ocultar thumbs Ver también para PURITY C Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
6 By-Pass and Capacity Tables
The capacity tables for the PURITY C Quell ST, PURITY C Finest and PURITY C Steam filter systems
are provided on pages 2–7.
The PURITY C1000 AC and PURITY C50 Fresh filter systems have a filter capacity of 10,000 and
15,000 litres respectively, regardless of the carbonate hardness and the by-pass set. All intake water
is filtered.
The filter system PURITY C500 MinUp has a capacity of 30,000 litres, irrespective of carbonate
hardness and with a bypass setting of 0 %. All the intake water is filtered.
Note: The stated capacities were tested and calculated based on standard application and machine
conditions. This information may vary according to external influencing factors (for example fluctuating
water quality and/or machine type).
7 Repair
Regularly check the filter system for leaks. Regularly check the hoses for kinks.
Bent hoses must be replaced.
The complete filter system must be replaced in rotation after a maximum of ten years from date
of purchase. The hoses must be replaced in rotation after a maximum of five years.
Caution: Before replacing filter systems or hoses, read the technical data (Chapter 9) and the
!
operating and safety information (Chapter 3).
Regularly clean the outside of the filter system with a soft, damp cloth.
Caution: Do not use any abrasive chemicals, cleaning solutions or astringent cleaning agents.
!
8 Troubleshooting
8.1 No water flow
Cause:
Water intake closed.
Troubleshooting:
Open the water intake at the upstream stop valve or by closing the locking
handle
8.2 No or low water flow in spite of open water intake
Cause:
Mains pressure too low.
Troubleshooting:
Check mains pressure. If the fault persists, check the filter system and filter
cartridge and replace if necessary.
Cause:
Filter head not mounted in direction of flow.
Troubleshooting:
Dismantle filter head and install in direction of flow (Chapter 4).
8.3 Leak
Cause:
Screwed connections not fitted correctly.
Troubleshooting:
Check mains pressure. Check all screwed connections and mount according to
Chapter 4. If the fault persists, replace filter system.
on the filter head
.
2
1
EN
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity c quell stPurity c finestPurity c steamPurity c freshPurity c acPurity c minup ... Mostrar todo

Tabla de contenido