6. Using even pressure, push down on the
bottom half of the unit. Keep pushing
down until the unit snaps onto the hooks
along the bottom of the mounting plate.
7. Again, check that the unit is firmly
mounted by applying slight pressure to
the left and the right-hand sides of the
unit.
If refrigerant piping is already embedded in
the wall, do the following:
1. Hook the top of the indoor unit on the up-
per hook of the mounting plate.
2. Use a bracket or wedge to prop up the
unit, giving you enough room to connect
the refrigerant piping, signal cable, and
drain hose. Refer to Fig. 3.13 for an ex-
ample.
3. Connect drain hose and refrigerant piping
(refer to the refrigerant piping connection
section of this manual for instructions).
4. Keep pipe connection point exposed to
perform the leak test (refer to the electri-
cal and leak checks section of this
manual).
5. After the leak test, wrap the connection
point with insulation tape.

The unit is adjustable

Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of
the unit. If you find that there is not enough room to connect embedded pipes to the indoor
unit, then the unit can be adjusted left or right by about 30 to 50 mm (1.25 to 1.95 in), de-
pending on the model. (See Fig. 3.14)
30 to 50 mm
(1.2 - 1.95 in)
108
6. Remove the bracket or wedge that is prop-
ping up the unit.
7. Using even pressure, push down on the
bottom half of the unit. Keep pushing
down until the unit snaps onto the hooks
along the bottom of the mounting plate.
Move to the left or right
Wedge
Fig. 3.13
30 to 50 mm
(1.2 - 1.95 in)
Fig. 3.14