PERFORMANCE DATA PBS-400
This system has been tested according to NSF/ANSI 42 and
53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
Max.
Influent
Permissible
Challenge
Product Water
Substance
Concentration
Concentration
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulate,
Class I
at least 10,000
particles
particles/mL
0.5 to <1
µm
Standard 53—Health Effects
Minimum
Cysts*
50,000/L
Lead 8.5
0.15 mg/L ± 10%
0.010 mg/L
Lead 6.5
0.15 mg/L ± 10%
0.010 mg/L
*NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
NOTE: This installation must comply with all applicable state
and local regulations.
NOTE: Maximum working pressure 125 psi.
NOTE: Do no use with water that is microbiologically unsafe
or unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on waters that may contain
filterable cysts.
NOTE: Testing was performed under standard laboratory
conditions, actual performance may vary.
NOTE: This drinking water system must be maintained
according to manufacturer's instructions, including
replacement of filter cartridges.
NOTE: An absorption product used will not be regenerated
for reuse. If an absorption product is affected by
chlorine, the water supply should be treated to
remove chlorine before introducing the filter.

CALIFORNIA PROPOSITION 65 WARNING

This product contains chemicals known to the
WARNING:
State of California to cause cancer or birth
defects or other reproductive harm.
EPA Est. No. 002623-IL-002
4 •
EVERPURE PBS-400 Water Filtration System
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥ 50%
>97.6%
≥ 85%
>99.9%
99.95%
99.99%
>99.99%
94.1%
>98.5%
98.9%
>99.7%
The PBS-400 is tested and Certified by NSF
International against CSA B483.1 and NSF/
ANSI standard 42 and 53 for the claims
specified on the performance data sheet.