FIGURE 18: Heatstar JET SERIES Burner Internal Wiring
•
If any of the original wire as supplied with the appliance must be replaced, it must be replace with wiring material having a temperature
rating of at least 105°C and 600 volts.
•
Each burner must be electrically grounded in accordance with the
National Electric Code ANSI/NFPA -70 or current Canadian Electrical-
Code, CSA C22.1.
BLACK
L1
WHITE
N
GREEN
Earth Ground
CONNECTION DIAGRAM
IGNITER / FLAME SENSOR
BURNER
BLACK
T1
BLACK
RED
WHITE
GREEN
BLACK
120V
24V
LED
LED
WHITE
WHITE
BLACK
GREEN
GREEN
GREEN
L1
IGN
PCB
24 VAC
TH
PCB
T'STAT (Optional)
JUMPER (Optional)
Enerco | Heatstar AG Series Heater
Chassis Wiring Is 18 AWG / 105 Degrees C / @ 600 Volts
Earth &
Igniter Wire Is 16 AWG / 25 KVDC / 10 KVDC
Chassis Ground
Crimp Caps Are # CE5 / 105 Degrees C
ORANGE
Replace Any Wiring With Same Ratings
All Quick Connects Are Fully Insulated (Except Igniter)
GAS VALVE
GREEN
GREEN
RED
M
BLACK
YELLOW
BLUE
YELLOW
Pressure Switch
LADDER DIAGRAM
L1
PCB
IND
M
PCB
120V
LED
IGNITER/FLAME SENSOR
T1
BURNER
PRIMARY - 120V
SECONDARY - 24V
PCB
PSW
PCB
PRESSURE SWITCH
V1
V2
GV
PCB
24V
LED
12
Operating Instructions and Owner's Manual
To Thermostat
(Optional)
RED
24V
W
FC-
IGN
FC+
V2
LED
GND
24 VAC
L1
IND
NC
V1
PSW
TH
CONTROL BOARD
RED
N
GND
PCB
Earth &
Chassis Ground