HeatStar JET Serie Instrucciones De Operacion Y Manual Del Propietario página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 2: Heatstar JET Parts Overview
Assemble the heater components as shown in Figures 2A, 2B. Install appropriated suspension hardware, beam clamps, chain or rod at
predetermined locations. Adjustment of chain length will provide uniform pitch.
10' 2-1/2"
Assembly Overview
20 ft. Exchanger length. 21 ft. - 4 in. Total Heater length. Six suspension points as indicated.
HANGER
Arrow Indicates Suspension Point
Figure 2A JET20
Assembly Overview
25 ft. Exchanger length. 26 ft. - 4 in. Total Heater length. Seven suspension points as indicated
HANGER
ALUMINIZED TUBE 3.5"
Arrow Indicates Suspension Point
Figure 2B JET25
Burner Housing
Must always be
installed horizontally.
Reflectors
Alternate overlap as shown on
overview. Length of reflector
and amount of overlap is
indicated. Reflector with
retention wire to be used
closest to burner box. See
instructions included with
tube set
Tube and Reflector Hanger
2 hangers required for each tube,
different sized hangers for different
sized tubes.
Tube Coupling Assembly
Coupling should be oriented with
slide bar on top.
(Only used on JET25)
HANGER
10' 2-1/2"
Reflector
ALUMINIZED TUBE 3"
HANGER
10' 2-1/2"
Reflector
Flange
Enerco | Heatstar AG Series Heater
ALUMINIZED (ONLY first 10 ft.) and HOT ROLLED STEEL
Heat Exchanger Tubes
Supplied in 10 ft. lengths (5' included with Jet25)
When hanging the tubes you will notice a weld seam down
the length of the tube. When assembly the tubes together is is
important to not have this weld seam face directly up or down, this
will increase the longevity of your heat exchangers.
Turbulator Assembly
Heatstar AG Jet heaters ship with turbulators loose in box. Turbulator is to
be placed into end of tube after tube assembly.
HANGER
2-1/2"
OVERLAY TYP
Flange
HANGER
HANGER
10' 2-1/2"
Reflector
HRS TUBE 4"
6
Operating Instructions and Owner's Manual
*JET25 ONLY*
HANGER
10' 2-1/2"
Reflector
HRS TUBE 3.5"
(1) 7' Turbulator Section
Located at the End of Tube Set
HANGER
5' 2"
Reflector
Coupler
HRS TUBE 4"
(1) 10' Turbulator Section
Located at End of Tube
Vent Cap
Vent Cap

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Jet20Jet25