Release the ON/OFF key and hold down the SCAN/CAL key:
a. the X-axis LED flashes green
b. after 3 seconds, the Y-axis LED flashes green once.
c. release the SCAN/CAL button
d. then the Y/Z axis LED remains green continuously
2. When the power LED flashes green, the unit starts to
level.
3. When self-leveling is complete, the Y/Z axis LED and
the power LED are solid green, the rotor starts to rotate
and emit the laser beam.
At this point, you can start calibrating the instrument
along the Z axis: by pressing the keys, bring the laser
to the intermediate altitude between "B" and "C".
4. When calibration is complete, press the SCAN/CAL key
again to save the adjustment data and exit the calibra-
tion mode; the instrument will turn off.
NOTES :
- After calibration, it is necessary to perform the vertical
check again to be sure of the accuracy. If the error per-
sists, repeat the calibration procedure.
- During calibration, the SCANNING/SPOTTING/ TILT/
SLOPE/ SPEED functions cannot be activated and exe-
cuted.
- During calibration, pressing the Power key will exit the
calibration phase, but the data will not be saved.