9.5 - AUTOMATIC CLOSURE (DEFAULT: 0 – FUNCTION DEACTIVATED)
If this function is activated, the device automatically closes the door after the set period of time.
Prior to closing the door, the device emits BEEPs for 20 seconds.
ATTENTION: to activate this function the photocell must work correctly.
If the photocell is not installed, the terminals IR1 and IR2 must be bridged with the common (GND).
+
-
+
Press the
key,
7
the display shows
30"
60"
90"
Select the desired pause time using the
9.6 - MAINTENANCE ALARM (DEFAULT: 0 – FUNCTION DEACTIVATED)
If this function is activated, the device emits BEEPs when the motor reaches 2000 operational cycles.
This alarm may be useful for scheduling maintenance operations.
To interrupt the alarm , simply press and hold the START button for 5 seconds, or power off the device for several seconds.
+
-
+
Press the
key,
8
the display shows
9.7 - CONDOMINIUM FUNCTION (DEFAULT: 0 - FUNCTION DISABLED)
m
CAUTION: To enable the condominium function it is necessary to activate the automatic closing
The condominium function provides the following operation logics:
1 - during the opening phase any start command is ignored
2 - during a pause a start command re-charge the pause time
3 - during the closing phase a start command causes the door movement to reverse
+
-
+
Press the
key,
9
the display shows
+
-
0
Press the
key:
flashes
to indicate that the
function is deactivated
120"
150"
180"
+
-
and
+
-
0
Press the
key:
flashes
to indicate that the
function is deactivated
+
-
Press the
key:
0
flashes to indicate that
the function is deactivated
+
Press the
key to activate
the function: the display
I
shows
corresponding to
30 seconds
210"
240"
keys
+
Press the
key to activate
the function: the display
I
shows
+
Press the
key to activate
the function: the display
I
shows
- 23 -
+
-
+
-
Press the
key to save
the settings.
7
The display shows
+
-
Press the
key to save
the settings.
The display shows
+
-
Press the
key to save
the settings: the display
shows
+
-
8
+
-
9