on the thermostat firstly and mounted on screws. After the installation is
finished, please unplug the thermostat cable and check if the gas water heater
could not be started. Then re-connect the thermostat cable, turn on the water
tap to check if the water heater could be started normally. This procedure
ensures the correct operation of the water heater before use.
 When flue blockage protection takes effect, please wait 2 to 3 minutes for
thermostat reset and ensure a good ventilation inside the room before restarting
the water heater. To restart the water heater, just need to turn on the water tap
again。

Operation

1. Preparation before Ignition
⑴ Make sure the gas type used complies with what's specified in
the label.
⑵ Make sure the ventilation holes and the exhaust fan are open.
⑶ Turn on the gas inlet valve.
2. Turn on the water valve (make sure there is water flowing out
of the sprayer), and then with automatic sparking action the
burner is ignited and hot water flows out. If the water
pressure is too low, or there is no battery, the appliance will
not start to operate.
 After initial installation or change of gas tank, air may remain
in the gas pipe and it requires several ignition attempts to
purge the residual air before the gas can be ignited.
 Were it the first ignition attempt fails, wait 10-20 seconds before the next
attempt.
Note: the ignition process for this product includes 3 steps,
during which the flame status would change subsequently. This
action lasts for several seconds and it's normal. Maximum ignition
safety time is 8s.
Attention:
Low battery would cause ignition failure or even ignition noise,
please replace the batteries in time before it's literally obsolete.