Parameter
Description of parameter function
Number
parameter value → Behaviour of the parameter
INPUT
Showing of input status (picture 5)
LL
Configuration level
0 → BASIC shows You only a part of the parameters (ones not marked by A)
1 → ADVANCED shows You all parameters
02
Automatic closing after pause time
0 → OFF not automatic closing
1-15 → numers of reclosing chance
99 → it always reclosing
03
Automatic closing after blackout
0 → OFF it does not close when the power comes back
1 → ON it closes when the power comes back
04
STEP BY STEP (PP)
0 → OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → PP CONDOMINIUM, when it is completely opens, it renews pause time
2 → PP CONDOMINIUM, when it is completely opens, it closes
3 → OPEN – CLOSE – OPEN - CLOSE
4 → OPEN – CLOSE – STOP – OPEN - CLOSE
05
Preflashing
A
0 → flashing light start to flash when the gate moves
1-60 → SECOND anticipate time of preflashing before the gate moves
99 → in opening not enables, 5 seconds preflashing in closing
06
PP Condominium Pedestrian
A
0 → pedestrian makes: OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → pedestrian always open
07
Deadman
A
0 → normal function
1 → the gate moves only if You press the button OPEN and CLOSE
08
Open gate led (SC)
A
0 → when the gate is closed the led is switch off, otherwise the led is fixed on
1 → slow flashing in opening, fast in closing and fixed when the gate is completely open, double flashing
when the gate stopped in the middle of the travel
10
Length travel learning (You have to do that when the gate is in the middle of his travel)
To make the travel lenght learning You have to set the value to 1 and You have to confirm it by S3, after we
see flashing all numbers and push the PP. The motor will make a complete opening and closing in slow-
down, if the process is made in right mode, the parameter comes back to 0. If the display shows You _E, it
means that the process is failed, and You have to repeat it
11
Slow-down travel
A
1-20 → PERCENTAGE of slow-down travel respect of normal speed
13
Tollerance of the position in which the gate it is consider closed
A
1-99 → MILLESIMUM respect of total travel
15
Lenght of pedestrian travel
A
1-99 → PERCENTAGE of pedestrian opening respect of normal travel
21
Pause time before automatically reclosing. When one of the photocells is darkened, the timer of pause
time is stopped, when the beam of photocells is restored the timer starts again the counting of pause time.
0-90 → SECONDS of pause time before of automatically reclosing
92-99 → from 92 the second number shows You the MINUTES of pause time before of automatically
reclosing (from 2 to 9 minutes)
27
Inversion time after the contact with safety edge or anticrushing
A
0-99 → inversion SECONDS
31
Torque level during the normal travel
1-8 → LEVEL
32
Torque level during the slow-down
A
1-8 → LEVEL
33
Torque level during the start up
A
0 → start up not enable
1-8 → LEVEL
34
Configuration of start up to avoid the tear on starting
A
0 → soft start not enable
1 → soft start
2 → slow soft start
(1 = minimum... 8 = maximum)
(1 = minimum... 8 = maximum)
(1 = minimum... 8 = maximum)
12
Default Value
0
0
0
0
0
0
0
0
0
10
10
30
30
2
5
8
8
2