Roger Technology H70/103AC Instrucciones De Uso página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CONNECTIONS TABLE
AP – COM
normally open contact
CH – COM
normally open contact
PED – COM
normally open contact
ORO – COM normally open contact
ANT
central pole of the cable
COM
shield
PP – COM
normally open contact
ST – COM
normally close contact
COS1 – COM normally close contact
COS2 – COM normally close contact
FT1 – COM
normally close contact
FT2 – COM
normally close contact
SC – COM
24Vcc MAX. 2W
24V
+24Vcc MAX.300mA
COM
0V MASSA
AP-COM-CH 230Vac 50Hz
COR
Tension free contact 5A
LAM
Tension free contact 1A
F-N-
230Vac 50Hz
PHOTOCELLS CONNECTIONS
ANT
COM
PP
ST
COS1
COS2
FT1
FT2
COM
SC
24V
OPEN INPUT BUTTON
CLOSE INPUT BUTTON
PEDESTRIAN OPENING INPUT BUTTON
CLOCK INPUT
ANTENNA
We recommend the use of RG58 coaxial cable (50Ω)
STEP BY STEP BUTTON
STOP BUTTON
SAFETY EDGE 1 CONNECTION (OPENING)
SAFETY EDGE 2 CONNECTION (CLOSING)
PHOTOCELL 1 CONNECTION
PHOTOCELL 2 CONNECTION
OPEN GATE LIGHT CONNECTION
slow flashing in opening, fast flashing in closing and fixed when
the gate is open, double flashing with gate stopped in the
middle of the travel
POWER ACCESSORIES (e.g. photocells)
MOTOR POWER
MOTOR CAPACITOR
COURTESY LIGHT CONNECTION
FLASHING LIGHT CONNECTION
CONTROL UNIT POWER
THE CONTROL UNIT SHOULD NOT BE SUPPLIED WITH
GENERATOR THAT DOES NOT WARRANT THE 50Hz
FREQUENCY WITH A NETWORK-COMPARABLE ACCURACY