During preheating for floor, all the buttons except OK is invalid. If you
want to turn off the preheating for floor, please press OK, then the
page will displayed as following:
13.2 PREHEATING FOR FLOOR
Do you want to turn of the
preheating for floor function?
NO
CONFIRM
OK
Using ◄、►to scroll the cursor to YES and press OK, the
preheating for floor will turn off.
Before floor heating, if large amount of water remain in the floor, the
floor may be deformed or even rupture during floor heating operation,
in order to protect the floor, floor drying is necessary, during which
the temperature of the floor should be increased gradually.
If FLOOR DRYING UP is selected, after press OK ,the page will
displayed as following:
13.3 FLOOR DRYING UP
WARM UP TIME(t_DRYUP)
KEEP TIME(t HIGHPEAK)
PEAK TEMP.(T_DRYPEAK)
START TIME
START DATE
SCROLL
When the cursor is on WARM UP TIME(t_DRYUP), KEEP TIME
(t_HIGHPEAK), TEMP. DOWN TIME(t_DRYD), PEAK TEMP.
(T_DRYPEAK), START TIME or START DATA, Using ◄、►、▼、
▲ to scroll and adjust the parameter.
t_DRYUP is the day for warming up;
t_HIGHPEAK is the day that high temperature last;
t_DRYD is the day for droping temperature
T_DRYPEAK is the target peak temperature of water flow during
floor drying up.
The target outlet water temperature during floor drying up described
in the picture below:
T1S
T_DRYPEAK
t_DRYUP
When the cursor is on OPERATE FLOOR DRYING UP?, Using ◄、
► to scroll to YES and press OK, the page will be displayed as
following:
13.3 FLOOR DRYING UP
The unit will operate floor
drying up on 09:00 16-12-2015.
CONFIRM
OK
YES
SCROLL
8 days
5 days
45°C
15:00
01-05-2015
1/2
t_DRYPEAK
t_DRYD
During floor drying up, all the buttons except OK is invalid. When the
heat pump malfunction, the floor drying mode will turn off when the
backup heater and additional heating source is unavailable. If you
want to turn off the floor drying up, please press OK, then the page
will displayed as following:
The unit will operate floor
drying up on 09:00 16-12-2015
Using ◄、► to scroll the cursor to YES and press OK, the floor
drying up will turn off.
6.21 AUTO RESTART
■ About AUTO RESTART
The AUTO RESTART function is used to select whether the unit
reapplies the user interface settings at the time of the power supply
returns after power supply failure.
■ How to set the AUTO RESTART
Go to MENU> FOR SERVICEMAN>AUTO RESTART.
Use ▼、▲、◄、► to scroll and use OK to select YES or NON to
enable or disable the auto restart function. If the auto restart function
is enabled, when power returns after a power supply failure, the
AUTO RESTART function reapplies the user interface settings at the
time of the power supply failure. If this function is disabled, when
power returns after a power supply failure, the unit won't auto restart.
6.22 Nouns illutration
The nouns related to this unit illustrated in the table bellow
Parameter
T1
Outlet water temperature of backup heater
T1B
Outlet water temperature of additional heating source
T1S
Target outlet water temperature
T2
Temperature of refrigerant at outlet /inlet of plate heat exchanger when in heat
t
mode/cool mode
T2B
Temperature of refrigerant at inlet /out let of plate heat exchanger when in heat
mode/cool mode
T3
Temperature of tube at outlet/inlet of condenser when in cool/heat mode
T4
Ambient temperature
T5
Temperature of domestic hot water
Th
Suction temperature
Tp
Discharge temperature
Tw_in
Inlet water temperature of plate heat exchanger
Tw_out
Outlet water temperature of plate heat exchanger
AHS
Additional heating source
IBH1
The first backup heater
IBH 2
The second backup heater
TBH
Backup heater in the domestic hot water tank
Pe
Evaporate/condense pressure in cool/heat mode
41
13.3 FLOOR DRYING UP
CONFIRM
OK
14 AUTO RESTART
COOL/HEAT MODE
YES
NO
YES
NO
DHW MODE
SCROLL