Safety Messages to Installers and Users
instructions. Failure to do so may result in property damage, serious injury, or death.
To avoid electrical shock hazards, do not connect wires when power is applied.
To be an effective warning device, this product produces bright light that could be hazardous to eyesight. Do not stare
directly at the light. Rapid flashing could induce photosensitive epilepsy.
Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or
alternations are made.
WARNING - EXPLOSION HAZARD: Do not disconnect while circuit is live or unless the area is known to be free of
ignitable concentrations.
An Overview of the 225XL and 225XL-N: Models 225XL and 225XL-N
hazardous location warning lights are available in 24VAC/DC or self-detecting
120-240VAC. The units come standard in flashing mode and are field configurable
to steady.
These devices are intended for permanent installation and operation in
accordance with Title 46, Code of Regulations, Parts 110-113, or Title 33, Code
of Federal Regulations, Part 183, Sub-part I, Section 183.410, and the applicable
requirements of the American Boat and Yacht Council, Inc. and/or ANSI/NFPA 302,
"Fire Protection Standard for Pleasure and Commercial Motor Craft."
Certifications and Ratings:
• UL and cUL Listed for Class I, Division 2, Groups A, B, C and D; Class II Divi-
sion 2, Groups F and G; Class III; or non-hazardous locations.
• Type 4X, IP66 enclosure. Indoor or outdoor use.
• IP69K Compliant
• Marine Listed
• Model 225XL-N is NSF Certified (dome-up) for Splash Zones
and Non-food Zones to NSF/ANSI 2: Food Equipment.
• Electrical ratings: 0.38A (24VAC/DC), 0.21A (120VAC),
0.13A (240VAC).
• Certified Operating Temperature: -58°F to 150°F (-50°C to 66°C).
T-CODE AT MAX AMBIENT TEMPERATURE
UL/cUL Hazardous Location Rating
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
Class III
Products should be installed by a licensed electrician and follow all safety
:
40°C
55°C
66°C
T6
T5
T4A
T6
T6
T6
T6
T6
T6
Elliptical
Outer Dome
with 12"
Curvature
Radius
Fresnel
Lens
PCBA
Silicone
Gasket
Zinc Alloy
E-coated
Base
Elliptical
5.5"/ 139.7 mm
Outer Dome
with 12"
Curvature
Radius
LED
Lamp
Inner
Fresnel
Lens
1/2"
NPT Pipe
Mount

Publicidad

loading

Resumen de contenidos para Federal Signal Electraray 225XL

  • Página 1 Model 225XL and 225XL-N Electraray ® Hazardous Location LED Warning Light Installation and Maintenance Instructions Warranty: This product’s limited warranty can be found at www.fedsig.com/SSG-Warranty Limited Products should be installed by a licensed electrician and follow all safety Safety Messages to Installers and Users instructions.
  • Página 2: Electrical Connections

    Support. Defective products under warranty will be repaired or replaced at Federal Signal’s discretion. Lamp failures excluded. Product Returns: A return authorization is required from Federal Signal prior to returning the product. Contact your Authorized Distributor for more information or to request a product return.
  • Página 3: Garantía

    Español Modelos 225XL y 225XL-N Electraray ® Luz de advertencia LED para ubicaciones peligrosas Instrucciones de instalación y mantenimiento limitada: la garantía limitada de este producto se puede encontrar en www.fedsig.com/SSG-Warranty Garantía los productos deben ser instalados por un electricista Mensajes de seguridad para instaladores y usuarios autorizado, y se deben seguir todas las instrucciones de seguridad.
  • Página 4: Instalación

    Servicio de reparación: se requiere una autorización de devolución. Póngase en contacto con su distribuidor autorizado o con Atención al Cliente de Federal Signal. Los productos defectuosos bajo garantía serán reparados o reemplazados a criterio de Federal Signal. Las fallas de la lámpara están excluidas.
  • Página 5: Garantie Limitée

    Français Modèles 225XL et 225XL-N Electraray ® Feu d’urgence DEL pour zone dangereuse Consignes d’installation et d’entretien : la garantie limitée de ce produit peut être consultée sur le site www.fedsig.com/SSG-Warranty. Garantie limitée les produits doivent être installés par un électricien Messages de sécurité...
  • Página 6: Maintenance Et Entretien

    Federal Signal. Les pannes de lampes sont exclues. Retours de produits : une autorisation de retour est nécessaire de la part de Federal Signal avant de renvoyer le produit. Contactez votre distributeur agréé pour plus d’informations ou pour demander le retour d’un produit.

Este manual también es adecuado para:

Electraray 225xl-n